Updated on 2026/07/04

Information

 

写真a

 
KANZAKI YUI
 
Organization
Faculty of Medical Sciences Department of Health Sciences Assistant Professor
School of Medicine Department of Health Sciences(Concurrent)
Title
Assistant Professor
External link

Research Areas

  • Life Science / Medical technology assessment

Degree

  • 修士(保健学) ( 2021.3 Kyushu University )

Research History

  • Kyushu University 医学研究院保健学部門 Assistant Professor 

    2025.4 - Present

      More details

    Country:Japan

  • Kyushu University 医療技術部放射線部門 診療放射線技師 

    2021.4 - 2025.3

      More details

    Country:Japan

Education

  • Kyushu University   医学系学府   保健学専攻

    2019.4 - 2021.3

      More details

    Country:Japan

  • Kyushu University   医学部   保健学科

    2015.4 - 2019.3

      More details

    Country:Japan

Research Interests・Research Keywords

  • Research theme: Evaluation of Radiation Dose and Image Quality in Dual-Energy Subtraction Radiography

    Keyword: Two-shot dual-energy subtraction, One-shot dual-energy subtraction, Dual-layer FPD

    Research period: 2021.4 - Present

Papers

  • Improvement of lung nodule visibility using one-shot dual-energy subtraction chest radiography with dual-layer flat-panel detector: a phantom study Reviewed

    Takarabe, S; Kuramoto, T; Kanzaki, Y; Shibayama, Y; Yamasaki, Y; Kitamura, Y; Yoshikawa, H; Kato, T

    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE   2025.5   ISSN:2662-4729 eISSN:2662-4737

     More details

    Language:English   Publisher:Physical and Engineering Sciences in Medicine  

    Chest x-ray imaging is widely used for the diagnosis of chest diseases but has low sensitivity for detecting pulmonary nodules due to anatomical overlaps. Dual-energy subtraction (DES) imaging can improve nodule visibility by reducing bone obscuration. This study aims to evaluate the image quality of a new one-shot DES (OSDES) system with a dual-layer flat-panel detector compared with the widely used two-shot DES (TSDES) system. Chest phantom images of various simulated nodules (8,10, and 12 mm) were acquired using both DES systems at several exposure doses, lung regions, and two types of body sizes (standard and large). Independent observers evaluated the visibility of the nodules under each condition using visual grading analysis scores (VGASs). The VGASs of OSDES images were significantly higher than those of TSDES images across all nodule sizes, lung regions, exposure doses, and body sizes, except for the standard chest phantom with a 10-mm nodule and without ribs. In particular, the VGAS of an 8-mm nodule in the region with one overlapping rib of the standard sized phantom was 2.46 with OSDES and 1.03 with TSDES, with the visibility of the nodule being significantly improved with the OSDES system. Thus, the OSDES system, using a dual-layer flat-panel detector and one exposure, offers superior visibility of pulmonary nodules with reduced dose compared with the TSDES system, suggesting its potential for improved clinical diagnosis without motion artifacts.

    DOI: 10.1007/s13246-025-01561-x

    Web of Science

    Scopus

    PubMed

  • Correlation Between Contrast-Detail Analysis and Clinical Image Quality Assessment of Intrapulmonary Lesions in Dual-Energy Subtraction Chest Radiography Using the TwoShot Method: A Phantom Study Reviewed

    Kuramoto, T; Takarabe, S; Kanzaki, Y; Shibayama, Y; Yamasaki, Y; Kitamura, Y

    ACADEMIC RADIOLOGY   31 ( 5 )   2118 - 2127   2024.5   ISSN:1076-6332 eISSN:1878-4046

     More details

    Language:English   Publisher:Academic Radiology  

    Rationale and Objectives: Dual-energy subtraction (DES) imaging constitutes a technique that has demonstrated efficacy in enhancing the detectability of pulmonary nodules on chest radiographs. However, a simple and quantitative methodology for evaluating the clinical image quality of DES images is currently lacking. The objective of this study was to investigate the applicability of contrast-detail (C-D) phantom analysis to the visual clinical image quality evaluation of chest DES images. Materials and Methods: We employed a custom-made phantom incorporating the C-D phantom and a multipurpose anthropomorphic adult chest phantom. Two phantom sizes were utilized to simulate standard- and large-bodied adult patients for each phantom. The custom-made phantom images were scored automatically using dedicated software, yielding an inverse image quality figure (IQF<inf>inv</inf>) value. The multipurpose anthropomorphic adult chest phantom was employed in a visual grading analysis (VGA) study that was conducted by two experienced radiologists and five radiological technologists. Each nodule placed in the chest phantom image was rated on a 4-point Likert scale. Results: A statistically significant correlation was observed between the VGA scores of the seven observers and the obtained IQF<inf>inv</inf> values. Conclusion: The findings of this study suggest that DES image analysis of the C-D phantom possesses the potential to be utilized for the evaluation of clinical DES image quality based on chest lesion detectability.

    DOI: 10.1016/j.acra.2023.10.016

    Web of Science

    Scopus

    PubMed

  • Effect of high- and low-energy entrance surface dose allocation ratio for two-shot dual-energy subtraction imaging on low-contrast resolution Reviewed International journal

    Kanzaki Y., Kuramoto T., Takarabe S., Shibayama Y., Yoshikawa H., Kato T.

    Radiography   29 ( 1 )   240 - 246   2023.1   ISSN:10788174

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Radiography  

    Introduction: Dual-energy subtraction (DES) imaging can obtain chest radiographs with high contrast between nodules and healthy lung tissue, and evaluating of chest radiography and evaluating exposure conditions is crucial to obtain a high-quality diagnostic image. This study aimed to investigate the effect of the dose allocation ratio of entrance surface dose (ESD) between high- and low-energy projection in low-contrast resolution of soft-tissue images for two-shot DES imaging in digital radiography using a contrast-detail phantom (CD phantom). Methods: A custom-made phantom mimicking a human chest that combined a CD phantom, polymethylmethacrylate square plate, and an aluminum plate (1–3 mm) was used. The tube voltage was 120 kVp (high-energy) and 60 kVp (low-energy). The ESD was changed from 0.1 to 0.5 mGy in 0.1 mGy increments. Dose allocation ratio of ESD between 120 kVp and 60 kVp projection was set at 1:1, 1:2, 1:3, and 2:1. Inverse image quality figure (IQF<inf>inv</inf>) was calculated from the custom-made phantom images. Results: When the total ESD and aluminum thickness were constant, no significant difference in IQF<inf>inv</inf> was observed under most conditions of varied dose allocation ratio. Similarly, when the total ESD and the dose allocation ratio were constant, there was no significant difference in IQF<inf>inv</inf> based on the aluminum plate thickness. Conclusion: Using IQF<inf>inv</inf> to evaluate the quality of the two-shot DES image suggested that dose allocation ratio did not have a significant effect on low-contrast resolution of soft-tissue images. Implications for practice: The present results provide useful information for determining exposure conditions for two-shot DES imaging.

    DOI: 10.1016/j.radi.2022.11.007

    Scopus

    PubMed

Presentations

  • Two-shot dual-energy subtraction imagingの画質へ及ぼす高エネルギーと低エネルギーの線量配分の影響

    第9回福岡県診療放射線技師会学術大会  2023 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Country:Japan  

  • One-shot dual-energy subtractionイメージングにおける肺模擬結節の視認性の評価

    第79回日本放射線技術学会総会学術大会  2023 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

  • Two-shot dual-energy subtraction imagingの画質へ及ぼす高エネルギーと低エネルギーの線量配分の影響

    第50回日本放射線技術学会秋季学術大会  2022 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

  • Two-shot dual-energy subtraction法の線量配分が軟部画像の画質に与える影響

    第38回日本診療放射線技師学術大会  2022 

     More details

    Language:Japanese   Presentation type:Oral presentation (general)  

    Country:Japan  

Class subject

  • コンピュータープログラミング入門

    2026.4 - Present   Second semester

  • 画像解剖学演習Ⅱ

    2026.4 - Present   Summer quarter

  • 医用画像評価学

    2026.4 - Present   Second semester

  • 医用画像情報学演習

    2026.4 - Present   First semester

  • 医用電気電子工学実験

    2025.4 - Present   Second semester

  • 画像解剖学演習Ⅰ

    2025.4 - Present   First semester

  • 画像技術学実習

    2025.4 - Present   Second semester

  • 品質管理論

    2025.4 - Present   Second semester

  • 放射線管理学実験

    2025.4 - Present   First semester

  • 放射線機器学実験

    2025.4 - Present   First semester

  • 放射線技術科学入門Ⅰ

    2025.4 - Present   First semester

  • 放射線技術科学入門Ⅱ

    2025.4 - Present   Second semester

▼display all

FD Participation

  • 2025.9   Role:Participation   Title:保健学科とインクルージョンセンターとの連携について

    Organizer:Undergraduate school department

  • 2025.4   Role:Participation   Title:令和7年度第1回全学FD(新任教員の研修)

    Organizer:University-wide

Participation in international educational events, etc.

  • 2025.12

    九州大学

    第20回 国際フォーラム