九州大学 研究者情報
論文一覧
濵田 秀則(はまだ ひでのり) データ更新日:2024.04.25

教授 /  工学研究院 社会基盤部門 建設設計材料工学


原著論文
1. #野澤郁人、福永隆之、@大谷俊介、濵田秀則, 海水練りコンクリート中鉄筋への外部電源方式電気防食の適用に関する研究, 防錆管理、一般社団法人日本防錆技術協会, 第67巻, 11号, 367-373, 2023.11.
2. 濵田 秀則, @Volana Andriamisaharimanana, 山本大介、福永隆之, 30年超海洋環境下に暴露されたPCはり試験体の劣化性状について, コンクリート構造物の補修、補強、アップグレード論文集、第23巻, 23, 2023.10.
3. #原 将之, @橋本永手, @山路 徹, @小林 浩、@曽根幸宏, 濵田秀則 , 干満部に位置するコンクリート中鉄筋の腐食特性, 材料と環境, 72, 4, 115-120, 2023.04.
4. 濵田秀則、@山本大介、Pinta Astuti, Rafmita Sari Rafdinal, 塩害を受けたRC部材の断面修復に併用する埋設型亜鉛陽極の適用方法に関する一考察 ー異なる陽極の時間差適用についてー, 材料、Journal of the Society of Materials Science, Japan, https://doi.org/10.2472/jsms.72.273, 72, 4, 273-279, 2023.04, [URL], This paper discusses the effectiveness of zinc anode cathodic protection applied to RC beam specimens severely damaged by chloride attack. Based on the experiment, that is, the zinc anode cathodic protection is applied to the 41-year-old RC beam specimens exposed to natural marine environments, suitable application method of zinc anode is discussed. In the experiment, repair was performed in three stages. In the first stage, polymer-modified mortar was cast to replace existing concrete in the middle tensile part with zinc anodes embedded in the repair mortar. After protective current became stable value, the anodes were disconnected from steel bars for a year defined as the second stage. During the one year of second stage, the steel bar in the repair area remained be passive state, without any sign of corrosion. As for the third stage, additional zinc anodes were installed in the existing concrete part in order to protect the steel in old chloride contaminated concrete. From one-year observation after the application of zinc anodes in old concrete part, it is confirmed that “time lag application” could stop the corrosion of steel bar in both parts..
5. Amry Dasar, Dahlia Patah, Hidenori Hamada, Daisuke Yamamoto, Yasutaka Sagawa, Life performance of 40-years-old RC beams with different concrete covers and bar diameters in natural corrosion environments, Structures, https://doi.org/10.1016/j.istruc.2022.11.033, 46, 12, 2031-2046, 2022.12, [URL], This study entailed an experimental evaluation of the life performance of 40-year-old reinforced concrete (RC) beams with different concrete cover depths and tensile bar diameters. Beams that were naturally corroded in a marine environment were used in this study, and no artificial process was employed to accelerate the corrosion. Most existing evaluations of beams employ electrical acceleration, admixture, or exposure to designed chloride environments to aid corrosion. Given the paucity of studies on naturally corroded beams, this study is of significance regarding the design, service, and life assessment of RC structures. Two-point load bending test was employed to examine the residual mechanical performance. The corroded bars were extracted to assess the corrosion properties, while the mechanical properties were evaluated via a tensile test. The focus of this study was on evaluating the progress of deterioration and capacity loss in naturally aged beams. The results indicated that a concrete cover of 50 mm satisfies the requirements of a design service life of 50 years. Furthermore, the cross-sectional loss–ultimate capacity loss relationship is consistently linear for the RC beams. Thus, the estimation of ultimate capacity loss based on cross-sectional loss is acceptable in case of natural corrosion of the RC beams. Hence, the findings can contribute to the prediction of the life performance and maintenance of existing structures as well as to designing new structures..
6. Pinta Astuti, Rahmita Sari Rafdinal, Daisuke Yamamoto, Volana Andriamisaharimanana, Hidenori Hamada, Effective Use of Sacrificial Zinc Anode as a Suitable Repair Method for Severely Damaged RC Members Due to Chloride Attack, Civil Engineering Journal, https://doi.org/10.28991/CEJ-2022-08-07-015, 8, 7, 1535-1548, 2022.07, [URL], In many cases, the repair strategy by using sacrificial anodes for cathodic protection in real RC structures requires additional zinc anodes after several years due to the decreasing protective area. This experimental study evaluates the effectiveness of time lag application of sacrificial anode cathodic protection applied to RC beam specimens that deteriorated severely due to chloride attack. In the experiment, sacrificial anodes and cathodic protection (SACP) were applied to 41-year-old RC beam specimens exposed to natural marine environments in which the embedded steel bars were significantly corroded. The repair work was performed in three stages. Instant-off and rest potential tests of steel bars were conducted periodically to demonstrate the time-dependent depolarization value. In the first stage, a polymer-modified mortar as a patch repair material was cast to replace the concrete in the middle tensile part with small sacrificial anodes embedded in the mortar. After the protective current reaches an equilibrium state, the sacrificial anodes are disconnected from the steel bars for a year, defined as the second stage. During the one year in the second stage, the steel bar in the patch repair area remained passive, without any sign of corrosion. As for the third stage, additional sacrificial anodes were installed in the existing concrete part to protect the steel in it. From one year of observation after applying sacrificial anodes to old concrete parts, the time lag SACP application of both in patch and non-patch repair parts was clarified to be effective in stopping the corrosion of steel bar in both parts until 20–30 years based on the service life prediction..
7. #緒方 麟太郎、畠山 繁忠、佐川 康貴、@濵田 秀則, 傾斜型ループ継手の最大引張荷重および破壊性状予測に関する検討, コンクリート工学年次論文集、Vol.44, No.1, 44, 1, 823-828, 2022.07,  ループ鉄筋を傾斜配置させた傾斜型継手(傾斜型ループ継手)について,両引き試験による破壊機構から,最大引張荷重および破壊性状の算定式を提案した。また,傾斜型ループ継手を模擬した試験体について両引き試験を行い,算定式と比較した結果,提案する方法により継手の最大引張荷重および破壊性状を推定できる可能性が示された。また,従来型のループ継手と比べても傾斜型ループ継手の耐力は同程度であり,実構造物への適用の可能性が示された。.
8. 山本 大介、川端 雄一郎、泉 心太、濵田 秀則, 一軸,三軸持続圧縮応力を受けるコンクリートのASR 進展に伴う変形挙動, コンクリート工学年次論文集、Vol.44, No.1, 44, 1, 610-615, 2022.07, コンクリート構造物内においてASR 膨張が進展する場合,そのコンクリート内部は埋設鉄筋やコンクリートそのものに拘束されつつASR が進展する。このように複雑に内部拘束が働く場合,ASR 膨張が如何に進展するかについては,既往の知見が少なく維持管理上克服しなければならない課題である。そこで本研究では,一軸および三軸持続荷重条件下におけるASR 膨張挙動について,実験的な検討を行った。その結果,拘束条件が厳しくなるほどASR 進展に伴う変形が抑制される結果を得た。.
9. 濵田秀則、福永隆之、@山本大介、@大谷俊介, 海水練りコンクリート中鉄筋への電気防食の適用について, 防錆管理、一般社団法人日本防錆技術協会, 第65巻, 10号, 371-377, 2021.10, 世界気象機構(WMO)によると,昨今の爆発的な人口増加,開発途上国の工業化・生活の質的な向上により,現在の水の消費量は50年前の約3倍になっていると言われている。そのため,2025年までに世界の人口の3分の2にあたる人々が飲み水の確保さえ難しくなると危惧されている。コンクリートの製造においては年間数十億トンの淡水を消費しており、淡水の使用を少しでも減らすために積極的に海水を使用していくことが一つの解決策と言える。本検討は,海水で練り混ぜたコンクリート中の鉄筋を電気防食で防食することを想定した実験的検討である。まだ継続中ではあるが,これまでの実験データよりカソード分極による防食効果に加えて,鉄筋周囲の環境改善による腐食抑制効果も得られることが明らかとなってきた。本研究は九州大学と㈱ナカボーテックの協力研究として実施している。.
10. Adiwijaya, Hidenori Hamada, Yasutaka Sagawa, Daisuke Yamamoto, Evaluation of Seawater Mixing and Curing on Strength Characteristics and Porosity of Fly Ash Concrete, Proceedings of the 9th International Conference of Asian Concrete Federation (ACF2020/2021), Advanced & Innovative Concrete Technology", 2021.11, This paper presents the strength characteristics and porosity of concrete mixed with seawater and tap water incorporating Fly Ash (FA) with a water binder ratio of 40%, 50%, and 60%. The effect of seawater mixing, FA, and curing conditions such as tap water curing (TC), seawater curing (SC), and air curing (AC) on the strength performance of concrete was evaluated. Moreover, the total pore volume (porosity) and thermogravimetric-differential thermal analysis (TG-DTA) were also observed to verify the results of compressive strength of concrete cylinder specimens. Eight series of concrete mixtures using tap water or seawater as mixing water were prepared by OPC and FA as a binder specified in Japan Industrial Standard. Concrete specimens were demolded at 24 hours after casting, then cured in tap water, in seawater, and in air (20ºC, R.H. 60% controlled room). After certain curing of 28 days and 365 days, compressive strength was measured in accordance with Japan Industrial Standard. Based on the investigation result, it was obtained that seawater mixing improved the strength of OPC concrete and FA concrete up to 365 days in all curing conditions, in TC, SC, and AC. The Porosity of seawater-mixed OPC concrete and FA concrete was decreased compared to tap water-mixed concrete. It was also found that the mass change (weight loss) of hydration product (CH) of seawater-mixed OPC concrete was higher than that of tap water-mixed OPC concrete in TC and AC.
KEYWORDS: Seawater mixing, curing condition, strength, porosity, fly ash concrete.
11. 濵田 秀則, 福手 勤, 阿部 正美, 塩害により劣化した鉄筋コンクリート部材の補修効果に関する実験的考察, コンクリート工学論文集, 3, 2, 85-95, 1992.07, [URL], The salt attack on RC structure causes cracking and spalling of cover concrete due to the corrosion of embedded steel bars. The main purpose of this study is to evaluate the corrosion preventive effectiveness of the existing repairing method composed of coating of steel, patching by mortar materials and surface coating of concrete. The conclusions obtained from this study are as follows (1) Coating of steel does not have a significant corrosion preventive effectiveness in the repairing method. (2) The corrosion preventive effectiveness of the two concrete repairing materials used in this study is almost same. (3) The corrosion preventive effectiveness of the surface coating of concrete depends on cracks between concrete and patching mortar, that is, the effectiveness becomes greater with the cracks. (4) Moisture and chloride contents in concrete are significant factors which affect the corrosion preventive effectiveness of repairing..
12. 濵田秀則, 福手 勤, 石井 光裕, 混和材として分級フライアッシュを用いたコンクリートの基礎物性および海洋環境下における耐久性, 土木学会論文集, 1997 巻, 571 号, 69-78, 1997.08, [URL], フライアッシュはこれまでにコンクリート用混和材として使用されてきた. しかし, 近年その品質変動が大きくなったため, その利用が減少している. 本研究において対象とした分級フライアッシュとは, フライアッシュの原粉から粒径の小さい粒子 (最大粒径が20μm) のみを取り出したものである. 本研究は, この分級フライアッシュを港湾構造物をはじめ海洋環境下において建設される構造物へ適用していくための基礎的データを得ることを目的としている. 一連の実験結果より, 分級フライアッシュを用いたコンクリートは, フレッシュ時の性状および硬化後の性状が優れており, 港湾・海洋構造物へ適用していくことが十分可能であることが明らかとなつた..
13. 濵田 秀則, 福手 勤, R. N. Swamy, 谷川 伸, J. C. Laiw, 鉱物質混和材の混入およびコンクリート表面被覆の塩害防止効果の定量的評価に関する研究, 土木学会論文集, https://doi.org/10.2208/jscej.1996.538_169, 1996, 538, 169-181, 1996.05, [URL], 本研究は, 鉱物質混和材の混入あるいはコンクリートの表面被覆によるコンクリート中への塩化物イオンの浸透・拡散の抑制効果を, RC構造物の塩害防止効果の観点から定量的に評価することを試みたものである. 水セメント比を3水準変化させたコンクリート, 鉱物質混和材を混入したコンクリートおよびアクリルゴム系塗料により表面被覆を施したコンクリートに対して乾湿繰返し塩化物イオン浸透促進試験を実施した. また, これまでに多数の研究者により発表されてきた塩化物イオン浸透促進試験のデータを収集整理し, 本実験結果と比較検討した. これらの実験および文献調査の結果をもとに上記2手法の塩害防止効果の定量的評価を試みた..
14. 福手勤、濵田秀則、山本邦夫, 海洋環境に20年間暴露されたコンクリートの耐久性に関する研究, 土木学会論文集  442/V-16, pp. 43~52, 1992. 2, 442, V-16, 43-52, 1992.02, [URL], 海水の作用を長時間受けるコンクリートにおいて, セメントや練りまぜ水の種類の違いがコンクリートの強度特性, 化学組成, 鉄筋の腐食特性などに及ぼす影響について調べることを目的として, 各種のコンクリート供試体を製作し, わが国の一般的な海洋環境と考えられる久里浜湾において20年間の暴露試験を実施した. 本研究は, 暴露試験の結果に, 物理的, 化学的, 電気化学的な考察を加えてとりまとめたものである..
15. Hiroto Tado, Toru Yamaji, Atsushi Kobayashi, Yoshiyuki Kawase, Michio Yoshida, Hidenori Hamada, A Study on Evaluation Index of Cathodic Protection Effect in Port Steel Structure Based on Test Piece Survey Result, Materials Transactions, 10.2320/matertrans.C-M2021815], 62, 6, 774-780, 2021.06, The prevention rate (PR: the index calculated from the corrosion rate of the non-protection and protection time) is generally employed as the evaluation index of the effect of the cathodic protection of the port steel structures in Japan. When designing the cathodic protection, the prevention rate has been employed as 90% since ancient times. However, if the corrosion rate of the steel is sufficiently close to zero, it is considered that the prevention rate is theoretically close to 100%. In this paper, firstly, we investigated aging changes of the cathodic prevention effect for 4 years by using test pieces installed in Japanese 4 ports. We arranged aging changes of the evaluation index which showed as the effect of the cathodic protection based on the result. Next, based on the above survey results, by using a large number of test pieces (total of 650 pairs) installed at port facilities in the whole country, we grasped the actual condition of the effect of the cathodic protection and verified while comparing evaluation index which shows the effect of the cathodic protection.
On the result, it was considered that it was desirable to evaluate the effect of the cathodic protection as “corrosion rate during the cathodic protection” which is a state at the time of the cathodic protection and includes factors of time as the index of the effect of the cathodic protection. In addition, it was suggested that the value of “corrosion rate at the cathodic protection” as an evaluation index of the effect of the cathodic protection was about 0.01mm/y..
16. Shigetada Hatakeyama, Yasutaka Sagawa, Hidenori Hamada, Shinichi Hino, Mamoru Masaki, Yuji Sato, Development of Improved Loop Joint Applied for Precast PC Deck Slab, Journal of Advanced Concrete Technology Vol. 19, 644-654, June 2021, Japan Concrete Institute, doi:10.3151/jact.19.644, Vol. 19, No.6, 644-654, 2021.06, Ordinary “loop joint” applied to precast prestressed concrete (PC) deck slab tends to increase its thickness. By decreasing this thickness, the dead load of the deck slab can be reduced. Hence, we have developed an “improved (inclined) loop joint” that reduces the deck slab thickness. This study presents the results of static bending test of slab specimens to confirm the load-carrying behavior and wheel moving load test to examine the fatigue durability of precast PC deck slabs with improved loop joints. The bending load-carrying behavior satisfied the requirements for highways in Japan. In addition, in the wheel moving load test, no sudden increase in vertical deflection and joint opening was confirmed at a load step of 250 kN × 100 000 times equivalent to 100 years on an actual bridge. Moreover, there was no water leakage at the bottom surface of the deck slab during the water-filling test. Based on the test results, it was inferred that the required load-carrying behavior and fatigue durability could be retained for 100 years in the improved loop joint..
17. Amry Dasar, Dahlia Patah, Hidenori Hamada, Yasutaka Sagawa, Daisuke Yamamoto, Applicability of seawater as a mixing and curing agent in 4-year-old concrete, Construction and Building Materials, 259, 22 page, 2020.12, [URL], In certain scenarios, seawater may be the only mixing/curing agent available; hence, it is necessary to optimize conditions for its application in concrete structures. In this study, the applicability of seawater as a mixing and curing agent in 4-year-old mortar cement specimens is evaluated. Unlike previous studies, we focused on evaluating the long-term performance of reinforced mortar specimens exposed to seawater. Specimens comprised ordinary Portland cement (OPC), grand granulated blast furnace slag (GGBFS), and reinforced concrete with plain steel, epoxy-coated, or stainless-steel bars; they were subjected to wetting–drying cycles (mimicked for tidal/splash zones) in the laboratory, and the corrosion was evaluated through electrochemical techniques. The results indicate that the effect of seawater on corrosion activity is considerably higher as a curing agent than that as a mixing agent. Further, GGBFS exhibited better performance than OPC; similarly, epoxy-coated and stainless-steel bars exhibited better corrosion resistance than plain steel bars. The results obtained in this study highlight the need to study the application of seawater in concrete mixing..
18. 大谷俊介(㈱ナカボーテック), 吉田幸司(九州大学), サブリナ ハラハップ(九州大学大学院), 山本大介(九州大学), 濵田秀則, 海水練りコンクリート構造物に対する電気防食の運用に関する研究 ー試験開始から約250日までの結果ー, 防錆管理、一般社団法人日本防錆技術協会発行, 第64巻, 第11号, 404-410, 2020.11, 中東地域や離島などでは、淡水の確保が困難なため、海水を使用して製造する海水練りコンクリートの利用が望まれている。しかし、コンクリート中に塩化物イオンが含まれることから鉄筋腐食が進行する可能性がある。そのため本研究では、海水練りコンクリート構造物に対して建設当初から電気防食を適用することを想定して、効率的な電気防食の運用方法を検討するための実験を行った。これまでの結果として、海水練りコンクリート中の鉄筋は、小さな通電電流でも腐食の進行を抑えられることを把握した。.
19. @濵田秀則、#ダリア・パタ、#サブリナ・ハラハップ, コンクリートの練混ぜ水としての海水の適用性について, 材料と環境、Vol.68, No.10, 2019,  公益社団法人 腐食防食学会, ISSN 0917-0480, 68, 10, 274-279, 2019.10, 一般的には禁止されている、海水のコンクリート練り混ぜ水としての適用について、特に、コンクリート内部鉄筋の腐食抑制の視点から論じている。既往の実構造物事例などを示しつつ、適切な対策を講じることにより、海水の適用が可能であることを述べている。.
20. Tarek Uddin Mohammed, Hidenori Hamada, Toru Yamaji, Long-Term Durability of concrete Made with Slag Cements under Marine Environment, ACI Materials Journal, American Concrete Institute, 1-12, 2019.09.
21. #田土弘人、山路徹、小林厚史、川瀬義行、吉田倫夫、@濵田秀則, テストピース調査結果に基づく港湾鋼構造物における電気防食効果の評価指標に関する検討, 材料と環境、Vol.68, No.8, 2019,  公益社団法人 腐食防食学会, ISSN 0917-0480, 68, 8, 220-226, 2019.08.
22. Dahlia Patah, 濱田秀則, 佐川康貴, 山本大介, The Effect of Seawater Mixing on Corrosion of Steel Bar in 36-Yeras Old RC Beams under Marine Environment, コンクリート工学年次論文集, 第41巻, 2019.06, Visual observation, chloride ingress, porosity, and corrosion of steel bars in RC beam made with seawater and tap water were investigated in this paper based on 36 years of exposure under marine tidal environment. After long-term exposure, seawater mixing shows better performance against corrosion of steel bar as well as strength, concrete resistance, oxygen permeability and microstructure compared with tap water mixing. It shows high possibility to use seawater as mixing water with precautions, such as minimum 50mm in cover depth which has influence significantly for the service life of RC structure..
23. 田城亨, 山本大介, 濱田秀則, 佐川康貴, ASR膨張が生じたPC梁部材の変形性状およびコンクリートのひび割れ性状に関する実験的検討, コンクリート工学年次論文集, 第40巻, 2018.06.
24. 香田 真生, 青山 敏幸, 山本 大介, 濵田 秀則, 流電陽極方式における陽極被覆材の配合および乾湿条件が防食効果に与える影響に関する実験的検討, コンクリート構造物の補修、補強、アップグレード論文集、第17巻, 17, 225-230, 2017.10, 陽極を点状配置する流電陽極方式において,陽極被覆材の配合および乾湿条件の違いが防食効果に与える影響を確認する目的で実験を行った.陽極には亜鉛を用い,陽極被覆材には水酸化リチウムを添加したセメントモルタルを用いた方式を適用した.試験要因は,水酸化リチウムの添加量,外部からの水分供給の有無および鉄筋腐食の有無とした.通電開始から約半年間の結果より,各試験要因による影響が確認され,また乾湿条件の違いに関わらず,十分な防食効果が得られることが確認された.さらに,分極抵抗の測定により,鉄筋の腐食環境の改善が確認された一方で,分極抵抗と分極曲線により推定される腐食電流密度は,整合がとれた評価を得ることができなかった..
25. 上野 貴行, 佐川 康貴, 濵田 秀則, 山田 一夫, 川端 雄一郎, 流電陽極方式における陽極被覆材の配合および乾湿条件が防食効果に与える影響に関する実験的検討, コンクリート構造物の補修、補強、アップグレード論文集、第17巻, 15, 475-480, 2017.10, 陽極を点状配置する流電陽極方式において,陽極被覆材の配合および乾湿条件の違いが防食効果に与える影響を確認する目的で実験を行った.陽極には亜鉛を用い,陽極被覆材には水酸化リチウムを添加したセメントモルタルを用いた方式を適用した.試験要因は,水酸化リチウムの添加量,外部からの水分供給の有無および鉄筋腐食の有無とした.通電開始から約半年間の結果より,各試験要因による影響が確認され,また乾湿条件の違いに関わらず,十分な防食効果が得られることが確認された.さらに,分極抵抗の測定により,鉄筋の腐食環境の改善が確認された一方で,分極抵抗と分極曲線により推定される腐食電流密度は,整合がとれた評価を得ることができなかった..
26. Amry Dasar, Hidenori Hamada, 佐川康貴, 山本 大介, ELECTROCHEMICAL BEHAVIOR OF STEEL IN CRACKED CONCRETE – INFLUENCE OF CRACK WIDTH, COVER, EXPOSURE CONDITIONS AND SUPPLEMENTARY CEMENTITIOUS MATERIALS (SCMs), コンクリート工学年次論文集 第39巻 (2017), 第39巻, 1045-1049, 2017.07, Reinforced concrete prism with w/b ratio of 0.5 had dimensions of 150x150x500 mm, while concrete cover were 30 mm, 50 mm and 70 mm. The crack widths investigated were 0.3 mm and 0.5 mm. These specimens were exposed to three conditions: (1) dry-wet cycles in tap water; (2) dry-wet cycles in sea-water; and (3) continuously immersed in 3% NaCl solution. The results show crack width has influence at constant concrete cover. However, by increasing concrete cover, the crack width has less affected. Further, exposure condition and SCMs (BFS) has an effect particularly in high chloride environment..
27. Rahmita Sari Rafdinal, Hidenori Hamada, 佐川康貴, 山本 大介, EVALUATION OF EXHAUSTED CONDITION OF SACRIFICIAL ANODE EMBEDDED IN CONCETE BY CURRENT ACCELERATION METHOD, コンクリート工学年次論文集 第39巻 (2017), 第39巻, 955-960, 2017.07, This study was carried out to observe the service life of the galvanic sacrificial anode to protect steel bar from corrosion in concrete. Current acceleration method was used by adjusting the current demand 10 times higher than initial current of anode. Results show that by increasing the current demand by 10 times, it makes the service life of anode reduced significantly after 70 days of exposure. It means the higher current delivery function of anode, the service life of anode become shorter. Current acceleration method is effective to investigate the service life of anode in short time..
28. 山本 大介, Hidenori Hamada, Yasutaka SAGAWA, Tarek Uddin Mohammed, 異なる拘束条件下においてASRが生じたコンクリートのひび割れおよび力学的性能低下について, コンクリート工学年次論文集 第39巻 (2017), 第39巻, 883-888, 2017.07, コンクリート内部の拘束条件が,ASRによる表面ひび割れ,内部ひび割れおよび力学的諸性能へ及ぼす影響について検討を行った。本研究では5種類の拘束条件を設定したコンクリート供試体でのASR促進膨張試験が終了したものを用いた。詳細調査の結果,拘束力や拘束の方向性がASR損傷の進展に大きく関与し,ASR膨張やひび割れ密度,ひび割れ幅,およびひび割れの方向性などがその影響を大きく受けることを示した。またこれらに関連し,圧縮強度,静弾性係数および超音波伝播速度も拘束力および方向性の影響を大きく受けることを示した。.
29. 阪井 峻, 山本 大介, Hidenori Hamada, Yasutaka SAGAWA, ASR 膨張によりひび割れが生じたコンクリートの圧縮応力下におけるひずみ分布に関する研究, コンクリート工学年次論文集 第39巻 (2017), 第39巻, 889-894, 2017.07, 本研究では,アルカリシリカ反応(ASR)により生じたひび割れがコンクリートの力学的性質に及ぼす影響を明らかにするため,膨張量ごとの力学的性質,内部のひび割れ性状を詳細に調査した。また,圧縮載荷試験を行うと同時にデジタル画像相関法を適用し,ASRによる内部ひび割れとひずみ分布の特徴について考察した。その結果,ASRによる内部ひび割れは膨張開始初期に発生し,膨張に伴い力学的性質は低下した。また,ASRにより生じた水平方向と斜め方向ひび割れに大きな縦ひずみが確認できた。これにより,載荷によってひび割れが閉じ,それに伴い変形量が大きくなり,静弾性係数が低下したと推察した。.
30. 田土弘人, 遊佐公一, 山路徹, Hidenori Hamada, 新設時に流電陽極方式による電気防食を適用した桟橋上部工における長期追跡調査結果, コンクリート工学年次論文集 第39巻 (2017), 第39巻, 985-990, 2017.07, 犠牲陽極に亜鉛を用いた流電陽極方式の電気防食工法を新設時から適用した鉄筋コンクリート製桟橋上部工の梁部材を28年間に亘って追跡調査した。電気防食の適用開始から23年目には,コア試料を採取して中性化深さと塩化物イオン濃度を測定し,はつり調査により鉄筋の腐食状態を観察した。それらの調査結果を当該桟橋上部工の無防食の梁部材と比較したところ,無防食の梁部材に比べて電気防食を適用した梁部材は,腐食の進行を抑制していた。また,亜鉛防食板を設置した梁部材のコンクリートは中性化の進行がなく,鉄筋近傍における塩化物イオンは無防食の梁部材に比べて低濃度であった。.
31. Amry Dasar, Hidenori Hamada, Yasutaka SAGAWA, Daisuke YAMAMOTO, Deterioration progress and performance reduction of 40-year-olad reinforced concrete beams in natural corrosion environments, Construction and Building Materials, 149, 690-704, 2017.05, Deterioration progress and performance reduction were experimentally evaluated in 40-year-old corroded reinforced concrete (RC) beams. The corrosion process was natural, without acceleration by current application, admixture inclusion, or exposure to an artificial chloride environment. The mechanical performance of the beams was evaluated through a four-point bending test. The corroded steel reinforcing bars were extracted for corrosion evaluation and tensile testing. A good correlation was established between crack width and cross-section loss, as well as between cross-section loss and ultimate capacity loss. Furthermore, the relationship between deterioration progress and performance degradation with the exposure period for each deterioration stage was elucidated..
32. 山本 大介, Hidenori Hamada, Yasutaka SAGAWA, φ25mmおよびφ33mmの小径コアを用いたコンクリートの圧縮強度の変動に関する一考察, コンクリート工学年次論文集 第38巻 (2016), 第38巻, 381-386, 2016.07, 本研究では,φ25mmおよびφ33mmのコンクリート小径コアの圧縮強度に着目し,コア供試体の寸法や載荷方法(減摩載荷の有無)の違いが圧縮強度の変動に及ぼす影響について,実験的検討を行った。その結果,φ33mmで減摩載荷を行った場合に,最も圧縮強度の変動が小さいことが明らかとなった。また,小径コアの圧縮強度の許容誤差範囲を5.0N/mm2としたとき,これを満たすために必要となる供試体本数は4本~10本であり,その時に得られる試験値は,φ100mmのコアの強度に対し80~90%程度となることが分かった。.
33. 香田 真生, 青山 敏幸, 山本 大介, Hidenori Hamada, 約30年暴露されたRC梁への陽極を点状配置する流電陽極方式の適用による防食効果の確認実験, コンクリート工学年次論文集 第38巻 (2016), 第38巻, 1173-1178, 2016.07, 約30年暴露されたRC梁を用い,陽極を点状配置する流電陽極方式の適用による防食効果について,実験を行った。RC梁の引張鉄筋を主な防食対象として,陽極材には亜鉛を用い,陽極被覆材には亜硝酸リチウムを添加したセメントモルタルを用いたA・Bの2通りの方式を適用した。約11ヵ月の測定期間において,自然電位および分極曲線の測定結果から,引張鉄筋側の腐食環境の改善が確認された。また,分極曲線による不動態のグレード判定は,妥当な結果が得られた。一方,分極曲線にターフェル外挿法を適用した腐食判定と分極抵抗法による腐食判定.
34. Rahmita Sari Rafdinal, Hidenori Hamada, 佐川康貴, 山本 大介, EFFECTIVENESS OF STEEL SURFACE CONDITIONS ON CATHODIC PROTECTION BY SACRIFICIAL ANODE IN CONCRETE, コンクリート工学年次論文集 第38巻 (2016), 第38巻, 1197-1182, 2016.07, The purpose of this study was carried out to observe the effectiveness of initial condition (rustedor non-rusted) of embedded steel in partially-repaired concrete on sacrificial anode cathodic protection systems..
35. Amry Dasar, Hidenori Hamada, 佐川康貴, 山本 大介, RECOVERY IN MIX POTENTIAL AND POLARIZATION RESISTANCE OF STEEL BAR IN CEMENT HARDENED MATRIX DURING EARLY AGE OF SIX MONTHS -SEA-WATER MIXED MORTAR AND CRACKED CONCRETE-, コンクリート工学年次論文集 第38巻 (2016), 第38巻, 1198-1203, 2016.07, Sea-water contains high chloride ion concentration which can promote corrosion of steel bar. However, it has a potential to be used as mixing water. On the other hand, cracks should be avoided in reinforced concrete for durability reason..
36. 香田 真生, 青山 敏幸, 山本 大介, 濵田 秀則, 流電陽極方式における防食電流および電位変化の分布に関する実験的検討, コンクリート構造物の補修、補強、アップグレード論文集、第15巻, 15, 141-144, 2015.10, 本実験は,電気防食工法の流電陽極方式において,陽極位置からの防食電流および電位変化の分布を確認することを目的とし,陽極から一定間隔で変化させた距離に鋼材を配置した試験体を用い,各鋼材における電流量と電位を測定した.約320 日間の測定結果より,本実験の範囲では,気中環境における腐食鋼材に対する防食範囲として,陽極から150mm 位置の鋼材までは一定の防食効果が確認されたが,200mm 位置以降の鋼材においては効果が期待できないことが確認された..
37. Caronge Muhammad Akbar, Hamada Hidenori, Irmawaty Rita, Sagawa Yasutaka, Yamamoto Daisuke, Application of Sacrificial Point Anode for Prevention of Steel Corrosion in Cracked Concrete, Journal of Advanced Concrete Technology, 10.3151/jact.13.479, Vol. 13, 10, 479-488, 2015.10, The effectiveness of a commercially available sacrificial point anode for corrosion prevention of steel in cracked concrete is presented. Reinforced concrete prisms with dimensions of 150 mm x 150 mm x 500 mm were prepared with a water to cement ratio (W/C) of 0.4 showing crack widths ranging from 0.1 to 0.4 mm obtained by pre-cracking. These specimens were exposed to three conditions: (1) laboratory air (temperature of 20±2°C and relative humidity of 60%); (2) immersed in 3% NaCl solution; and (3) dry/wet cycles of above mentioned conditions. Measurements included the free corrosion potential, polarization behavior of the sacrificial point anode, anodic-cathodic polarization curve of the reinforcement steel and visual observation. The test results show that the sacrificial point anode was effective to prevent the embedded steel from corrosion in cracked concrete. Specimens exposed to dry/wet cycles or immersed in 3% NaCl solution demonstrated a better protection than those exposed to laboratory air due to the high moisture condition. Thus, a sacrificial point anode becomes active to protect the steel bars even in cracked concrete..
38. Adiwijaya, Hidenori Hamada, Yasutaka SAGAWA, Daisuke Yamamoto, EFFECT OF MINERAL ADMIXTURES ON CARBONATION OF SEAWATER MIXED CONCRETE, Proceedings of the 2nd Makassar International Conference on Civil Engineering (MICCE 2015)Makassar, Indonesia, August 11-12, 2015, 153-162, 2015.08, This study presents carbonation of seawater mixed concrete and tap water mixed concrete incorporating mineral admixtures such as Fly Ash (FA) and Ground Granulated Blast-Furnace Slag (GGBS) with W/B of 40%, 50% and 60% in tap water curing (TC), seawater curing (SC) and air curing (AC). The effect of seawater mixing, mineral admixtures, water-binder ratio, curing conditions and exposure condition on carbonation process of concrete were
evaluated. Concrete prism specimens using tap water and seawater as mixing water were prepared. At 24 hours after casting, specimens were de-molded and followed by distinct curing conditions such as tap water curing, seawater curing and air curing. After curing until 28 days, specimens were exposed in air during 4 weeks before they were brought into accelerated chamber for carbonation and natural outdoor exposure. Based on experimental result, it was shown that carbonation depth of seawater-mixed concrete with and without mineral admixtures in AC was lower compared to tap
water mixed concrete in both accelerated and natural exposure carbonation. Moreover, mineral admixtures increased carbonation rate of seawater mixed concrete in all curing condition. Besides, the carbonation rate of seawater-mixed concrete with and without mineral admixtures in SC was smaller than that of in TC. In addition, accelerated carbonation depth of seawater mixed or tap water mixed FA and GGBS concrete was seven times larger than natural exposure carbonation..
39. Mohammad Akbar Caronge, Hidenori Hamada, Yasutaka SAGAWA, Daisuke Yamamoto, APPLICATION OF SACRIFICIAL ANODE TO PREVENT MACROCELL CORROSION IN REPAIRED RC MEMBER, Proceedings of the 2nd Makassar International Conference on Civil Engineering (MICCE 2015)Makassar, Indonesia, August 11-12, 2015, 163-170, 2015.08, This paper presents results of an experimental investigation on the effectiveness of sacrificial anode to prevent macrocell corrosion of steel in repaired RC member. Experimental tests were carried out in reinforced concrete beams with sizes of 150 mm x 150 mm x 500 mm and cover thickness of 30 mm. Each specimen consisted of plain steel bar (PS), plain steel bar with sacrificial anode (PSCP) and epoxy coated steel bar (PSE). Mix proportion was divided into two categories; firstly, existing concrete (EC) with 4 kg/m3 and 10 kg/m3 of chloride and W/C ratio of 53.5% and 40% were placed, namely N53.5, N40 and BB40. For BB40, replacement of cement with 50% of blast furnace slag (BFS) was added. Secondly, concrete with 47% of W/C ratio without chloride was placed as repaired concrete (RPC). The potential value of steel, depolarization tests, anodic-cathodic polarization curve, polarization behavior of sacrificial anode, and visual observation were evaluated after one-year exposure. From the test results, PSCP showed good passivation film and little corrosion than PS in RPC. It means sacrificial anode is effective to delay macrocell corrosion repaired section. Also, replacement of cement by 50% BFS can raise the resistance to penetration of chloride ions into repaired concrete..
40. Nobuaki Otsuki, Hidenori Hamada, Nobufumi Takeda, Kei-ichi Imamoto, Toru Yamaji, Takashi Habuchi, Takahiro Nishida, INTRODUCTION OF A JCI TECHNICAL COMMITTEE REPORT ON THE USE OF SEAWATER IN CONCRETE, Proceedings of the 40th Conference on Our World in Concrete & Structures 27-28 August 2015, Singapore, 249-262, 2015.08, Effective use of resources is much needed. Particularly, water resources for drinking are predicted to be in serious shortage in 2050 due to increases in population and rapid urbanization throughout the world. In the field of concrete, billions of tons of freshwater is consumed annually for mixing, curing
and washing concrete. Seawater, which exists in abundance on the globe, is presently not permitted to be used for these purposes. Active use of seawater in the field would help more effective use of freshwater resources. The Committee aims to: 1) collect information on use of seawater, such as for mixing and curing concrete, and investigate problems and remedies via experiments and reference studies, 2) survey technologies for using seawater in manufacture and curing of concrete by interviews and literature searches, and 3) summarize and investigate the results, and propose various possibilities, etc., for effective use of seawater. In this paper, introduction of the committee report is presented...
41. Adiwijaya, Hidenori Hamada, Yasutaka SAGAWA, Daisuke Yamamoto, EXPANSION CHARACTERISTICS OF SEAWATER MIXED CONCRETE DUE TO ALKALI-SILICA REACTION, Proceedings of the 40th Conference on Our World in Concrete & Structures 27-28 August 2015, Singapore, 311-320, 2015.08, This paper presents expansion characteristics of seawater mixed concrete and tap water mixed concrete in tap water curing (TC), seawater curing (SC) and moisture curing (MC). Six series of concrete mixture with 50% waterbinder ratio were prepared. Ordinary Portland Cement (OPC), Fly Ash (FA) and
Ground Granulated Blast-Furnace Slag (GGBS) were used as binder, with replacement ratio of FA 30% and GGBS 50%, respectively. Andesite stone was
selected as a reactive coarse aggregate used in the pessimum proportion. Concrete cylindrical specimens were cured in TC, SC and MC in 40°C, 100% R.H. chamber, and expansion of specimens was measured in accordance with contact gauge method. Results showed that seawater mixed OPC concrete caused expansion due to ASR in TC, SC and MC. The expansion level of seawater mixed OPC concrete was larger in MC than that in SC and TC. However, ASR-induced expansion of seawater mixed concrete was inhibited by incorporating mineral admixtures..
42. Daisuke Yamamoto, Hidenori Hamada, Yasutaka SAGAWA, VARIATION AND ITS SUPPRESSION METHOD OF COMPRESSIVE STRENGTH OBTAINED BY SMALL DIAMETER CORE SPECIMEN, Proceedings of the 40th Conference on Our World in Concrete & Structures 27-28 August 2015, Singapore, 487-492, 2015.08, It is generally known that deviation of compressive strength test value increases when small diameter core specimen (25mm) is used. In this study, an
experimental study was performed, focusing on its deviation of compressive strength. As a result, following conclusions were obtained, (1) Compressive
strength of small diameter core tend to be larger if the coarse aggregate volume content of the specimen is higher, and (2) It is possible to control the variation of compressive strength to some extent by using anti-friction material. And then, the small diameter core compressive strength values with anti-friction material was found to be smaller compared to the 100mm core compressive strength values..
43. Rahmita Sari Rafdinal, Hidenori Hamada, Yasutaka SAGAWA, Daisuke Yamamoto, EFFECTIVE LENGTH OF CATHODIC PROTECTION EMBEDDED STEEL WITH SACRIFICIAL ANODE UNDER NON-HOMOGENEOUS CHLORIDE ENVIRONMENT, コンクリート工学年次論文集, 第37巻, 955-960, 2015.07, This study was carried out to identify the effective length of embedded steel reinforcement element which can be protected by sacrificial anode under non-homogeneous chloride environment in partially-repaired concrete. The investigations were conducted on four reinforced concrete beams with embedded steel element both in chloride free repair OPC concrete and chloride contaminated OPC existing concrete. The electrochemical test includes the protective current, macro-cell current density, depolarization and anodic polarization curve of sacrificial anode. The results show that sacrificial anode is effective to protect the corroding steel around 120 mm until 200 mm from the border between repair and existing concrete..
44. 香田真生, 青山敏幸, Daisuke Yamamoto, Hidenori Hamada, 流電陽極方式における陽極被覆材および乾湿条件が防食効果に与える影響に関する実験的検討, コンクリート工学年次論文集, 第37巻, 1549-1554, 2015.07, 本実験は,電気防食工法のひとつである流電陽極方式において,陽極材の被覆条件および乾湿条件の違いが防食効果に与える影響に着目し,陽極被覆材の選定実験,および選定した被覆条件における複数本の鉄筋に対する防食効果の確認実験を行った。陽極被覆材に亜硝酸リチウムを混入することによって,陽極材が活性化することが確認され,また混入量の減少にって防食効果が低下することが確認された。また,水分が供給される環境では亜鉛および鉄筋の電位が卑化するがことが確認された。さらに,本実験の範囲では,複数本の鉄筋を埋設した試験体において,選定した陽極被覆材を用いることで十分な防食効果が確認された。.
45. Muhammad Akbar Caronge, 山本 大介, 小林浩之, 大谷俊介, 濵田 秀則, Development of Steel Passivity in Concrete by Cathodic Protection with Environmental Improvement Effects, Proceedings of the International Conference on the Regenaration and Conservation of the Concrete Structures., CDのためページ掲載なし, 2015.06, The 100 mV decay potential is most widely used as cathodic protection (CP) criteria in reinforced concrete structure. However, in some cases the 100 mV decay potential criteria could not achieve due to the environment condition, even steel is protected. In this paper, the effect of environmental improvement on the steel surface as a secondary effect of CP was studied. Nine levels of constant current densities were applied on the steel bar embedded in concrete specimens with chloride ion of 2 kg/m3, 5 kg/m3 and 10 kg/m3. The instant-off potential (Eio), depolarization test, anodic-cathodic polarization curve and visual observation were evaluated. From test results, it was found that current density of 5 mA/m2, 10 mA/m2 and 20 mA/m2 is sufficient to achieve the 100 mV decay potential criterion at the beginning polarization time for concrete with chloride content of 2 kg/m3, 5 kg/m3 and 10 kg/m3 respectively. In the concrete with 10 kg/m3 of chloride, the decay potential slightly decreased at 230 days due to the diffusion of dissolved oxygen (DO). In addition, a small current density also improved the passivity film of steel bars..
46. Muhammad Akbar Caronge, 濵田 秀則, Yasutaka SAGAWA, 山本 大介, Sumargo, Deterioration Evaluation and Life-Extension Strategy of 77 Year-Old Concrete Structure Exposed to Indonesian Marine Environment, Proceedings of the International Conference on the Regenaration and Conservation of the Concrete Structures., CDのためページ掲載なし, 2015.06, Deterioration due to steel corrosion induced by chloride ion is the major cause of the damage of reinforced concrete structures exposed to marine environment. For this, a durability investigation of a 77 year-old concrete structure located in a tropical marine environment in an Indonesian port was carried out. Site investigation and laboratory testing that are commonly used in corrosion investigations were conducted to observe long-term performance of the concrete. A quantitative evaluation related to steel corrosion products was also observed by fluorescence microcscope. Results show that the principal mechanism responsible for the extensive deterioration of the structure studied is chloride-induced reinforcement corrosion. This mechanism lead to loss of rebar and concrete cross-section, loss of steel-concrete bond, cracking, delamination and spalling of concrete noted as the most common defect occuring at structure elements after being
exposed over for long-term period. Repair strategies for extending the service life of these
structures are also presented in this paper..
47. Tarek Uddin Mohammed, Hidenori Hamada, Ariful Hasanat, Mohammed Abudullah Al Mamun, Corrosion of Steel Bars in Concrete with the Variation of Microstructure of Steel-Concrete Interface, Journal of Advanced Concrete Technology, Japan Concrete Institute,, Volume 13, 230-240, 2015.04.
48. Mohd Isneini, Yasutaka SAGAWA, 山本大介, Hidenori Hamada, Experimental Study on Mitigating ASR byUsing Fly Ash and Silica Fume, 一般社団法人 九州橋梁・構造工学研究会、 公益社団法人 土木学会西部支部, 第30号, 149-156, 2014.12.
49. Hidenori Hamada, 山本 大介, Yasutaka SAGAWA, 池田 隆徳, An experimental study on relationship between chloride content in mortar and passivity condition of embedded steel bar, Proceedings of the fourth International Sysmposium on Life-cycle Civil Engineering, "Life-Cycle of Structural Systems: Design, Assessment, Maintenance and management", 1479-1484, 2014.11, In this study, properties related to corrosion of embedded steel in mortar, which contains chloride around threshold chloride content for steel corrosion, were discussed. Half-cell potential, polarization resistance and polarization curve of embedded steel were measured. Half-cell potential showed a linear relationship with chloride content in mortar. Polarization resistance and grade of passivity judged by polarization curve quickly decreased at the chloride content around 0.3 - 0.4% mass percent versus unit cement mass. This indicates that the destruction of passivity film on steel surface is occurred around this chloride level, which is believed pres-ently to be threshold chloride content for steel corrosion initiation..
50. 山路徹, Hidenori Hamada, S. Mizuma, T.Okabe, Corrosion resistant property of stainless steel bars in concrete under marine environment, Proceedings of the fourth International Sysmposium on Life-cycle Civil Engineering, "Life-Cycle of Structural Systems: Design, Assessment, Maintenance and management", 1524-1531, 2014.11, For the durability enhancement of port RC structures, corrosion resistant property of three types of stainless steel bars (SUS430, SUS304 and SUS316) in concrete was studied by the exposure tests under marine environment. Results obtained are as follows. i) No corrosion was observed at the sound part on all types of stainless steels under high concentration of chloride ion. Here, the threshold levels for corrosion were estimated larger than 13-14 kg/m3. ii) No corrosion was observed at the small cracked part on all types of stainless steels where the crack width was smaller than 0.5mm. On the other hand, slight corrosion was observed at the large crack regions where the crack width was larger than 0.5mm on SUS 304 and 316. iii) In case that stainless steel bar is applied to port RC structures, the life cycle cost can be lower than the case of carbon steel bar..
51. 小林 浩之, 山路 徹, 審良 善和, 大谷 俊介, 濵田 秀則, 湿潤環境下におけるRC電気防食基準への電位の適用に関する基礎的検討, コンクリート構造物の補修、補強、アップグレード論文集、第14巻, 14, 7-10, 2014.10, 湿潤環境下における鉄筋コンクリート(RC)構造物の電気防食基準について実験的検討を行った.電気化学測定によって得られた再不動態化電位ER(-650mV v.s. SSE)をもとに電気防食試験を実施した結果,鉄筋の電位をERよりも卑に分極した条件では,現行の100mVシフト基準を満たさなかったものの,腐食速度は0.2μA/cm2以下を示し,高い電気防食効果が得られることを確認した..
52. 山本 大介, 成田 一晃, 濵田 秀則, 佐川 康貴, 小径コアの圧縮強度試験値およびその変動に関する研究, コンクリート構造物の補修、補強、アップグレード論文集、第14巻, 14, 81-86, 2014.10, 既存コンクリート構造物の維持管理を行う際,その材料物性値として圧縮強度試験値が必要となることがある。しかし,構造物の配筋状態や部材厚さなどの制約から,φ100mm寸法のコンクリート供試体を採取できない場合があり,圧縮強度試験を小径寸法のコア供試体を用いて行わなければならない場合がある。一般に供試体寸法が変化すれば圧縮強度試験値も変化し,また小径になるほど圧縮試験値が安定せず変動することが知られている。そこで本研究では,圧縮試験供試体の寸法変化と圧縮強度の変動と制御手法について,供試体寸法,粗骨材体積含有率,粗骨材最大寸法の観点から整理を行い,実験的検討を行った。.
53. 山路 徹, 与那嶺 一秀, 審良 善和, 濵田 秀則, 海洋暴露試験に基づくコンクリート中の塩化物イオン拡散性状の時間依存性に関する検討, コンクリート構造物の補修、補強、アップグレード論文集、第14巻, 14, 213-220, 2014.10, 海洋環境下で長期間暴露されたコンクリート中の塩化物イオンの拡散性状については,見かけの拡散係数が時間とともに低減するといったことが報告されている.また,コンクリート品質や環境の状態によっては,塩化物イオンの浸透が停滞するといった報告もある.このように,実海洋環境での塩化物イオン拡散性状の時間依存性については,明確になっていないのが現状である.本検討では,複数の実海洋環境下(干満帯,飛沫帯)において,10年程度の長期暴露試験を行い,コンクリートの塩化物イオン拡散性状の時間依存性について検討を行った..
54. 溝渕 真之, 山本 大介, 濵田 秀則, 佐川 康貴, ASRを生じたコンクリートの損傷状態と力学的性質の関係に関する実験的検討, コンクリート構造物の補修、補強、アップグレード論文集、第14巻, 14, 53-60, 2014.10, 本研究では,アルカリシリカ反応によりコンクリートに生じたひび割れの発生状況とコンクリートの強度と力学的性質との関係を明らかにすることを目的とし,円柱供試体における膨張量ごとの力学的性質,ひび割れ性状の変化を詳細に調査した.また,実構造物から採取したコア供試体においても同様の実験を行い,両者の関係性を考察した.その結果,室内試験と実構造物では内部ひび割れの進展過程が異なることが示唆され,ひび割れ幅が大きく増加した損傷状態では圧縮強度と力学的性質,ひび割れ密度との相関関係は低下することが分かった..
55. Muhammad Akbar CARONGE, 濵田 秀則, 佐川 康貴, 山本 大介, EFFECT OF CURING AND CRACK WIDTH ON POTENTIAL PERFORMANCE OF STEEL WITH SACRIFICIAL ANODE IN CRACKED CONCRETE, コンクリート工学年次論文集、第36巻、2014, 36巻, 1204-1209, 2014.07, The effectiveness of sacrificial anode to protect embedded steel in cracked concrete under different curing conditions; air curing, immersion in a 3% NaCl solution and dry/wet cycle is presented. Reinforced concrete prism in size of 150x150x500 mm with water-to-cement ratio of 0.4 and pre-crack of 0.1 to 0.4 mm in width was evaluated. The result showed that sacrificial anode was effective to protect the embedded steel in cracked concrete. Also, crack width significantly influences the corrosion rate..
56. Nurazuwa MD NOOR, 濵田 秀則, 佐川 康貴, 山本 大介, STRENGTH CHARACTERISTICS AND EFFECTIVE CHLORIDE DIFFUSION COEFFICIENT OF RUBBERIZED CONCRETE, コンクリート工学年次論文集、第36巻、2014, 36巻, 1864-1869, 2014.07, In this study, crumb rubber was used as fine aggregate at 10%, 15% and 20% sand volume replacement to produce rubberized concrete with satisfied compressive strength. Rubberized concrete was tested on its fresh properties, mechanical strength and effective diffusion coefficient of chloride ion. In addition, silica fume as 10% of cement was added to investigate the effect on the strength and resistance against chloride penetration. Results shows mechanical strength reached to the acceptable value for satisfied strength as structural concrete and chloride ion resistance was improved with silica fume..
57. Nurazuwa MD NOOR, Daisuke Yamamoto, 濵田 秀則, 佐川 康貴, Potential in usage of used tire as sand replacement in high strength mortar, セメント・コンクリート論文集, 67, 573-578, 2014.03, Every year, tire generated from vehicles that is not biodegradable are increasing, and if it is not managed properly it could bring harm to the environment. Thus, this research was conducted to study the utilization potential of used tire as mortar material. Crumb rubber with size of 1 mm – 3 mm from waste tire was mixed as fine aggregate at 10% of sand volume in mortar mixture. In addition, silica fume was added as a binder at 10% and 15% of cement weight. Six series of cylindrical rubberized mortar specimen with size of 50 mm diameter and 100 mm height for compressive strength and 40 mm x 40 mm x 160 mm prism for flexural strength were prepared. Water to cement ratio was set at 0.35, 0.30 and 0.25 and all series were tested on its fresh properties, compressive strength, flexural strength, hardened density and elastic modulus. Results shows the strength of rubberized mortar without silica fume achieved more than 50% of control mixture strength and gave a good resistance against brittleness. Meanwhile, addition of 10% silica fume in the mixture helped to increase the strength. In conclusion, this study strongly suggests the potential of the crumb rubber to be used as sand replacement with or without silica fume..
58. Md Noor Nurazuwa, Yamamoto Daisuke, Goda Hiroki, ゴムチップ混和モルタルの強度特性とすり減り抵抗性に関する検討, 土木構造・材料論文集 九州橋梁・構造工学研究会論文集編集委員会 編, 29, 91-96, 2013.12.
59. Adiwijaya, 山本 大介, Amry Dasar, Hidenori Hamada, Yasutaka SAGAWA, Effects of Seawater Mixing and Curing on Strength and Carbonation of Fly Ash Concrete, 土木構造・材料論文集、第29号, 29, 97-103, 2013.12, In this study, effects of seawater mixing and seawater curing on compressive strength, porosity, and carbonation depth of concrete with 20% fly ash replacement were investigated. Concrete cylinder specimens with water-binder ratio of 0.5 were prepared using natural seawater or tap water as mixing water. At 24 hours after casting, specimen was demolded and followed by different curing conditions, such as tap water curing, seawater curing and air curing in 20C, RH 60% controlled room for 28 days. Result shows that compressive strength of concrete mixed with seawater at 28 days was improved compared with tap water mixed concrete for each curing condition and no significant difference in compressive strength of concrete is observed for tap water curing and seawater curing. In addition, a good correlation between compressive strength and carbonation coefficient in seawater mixed and tap water mixed concrete was also obtained..
60. 山本大介, Hidenori Hamada, Yasutaka SAGAWA, Nurazuwa Md Noor, Diagnosis of Load Bearing Capacity of Sewage Pipes Deteriorated by Sulfuric Attack, Proceedings of the Seventh International Conference on Concrete under Severe Conditions - Environment and Loading, Volume 2, 1280-1288, 2013.09, It has been frequently reported that concrete sewage facilities has deteriorated in short term than expected service life time of 50 years. This is serious problem in durability and maintenance of the sewage facilities. It is clear that this deterioration originates from sulfuric acid generated by the micro-organism activity in the sewage, thus nowadays a routine corrosion inspection of the sewage pipes is carried out. However, deterioration in sewage pipe has not well verified by current checking techniques, thus to ensure the required performance during service period is difficult. In this paper, the method for deterioration diagnosis for sewage pipes is investigated. As a result, the degree of deterioration can be examined, and methodology for estimation of service life with satisfy required performance of sewage pipe is proposed..
61. 池田隆徳, Hidenori Hamada, Yasutaka SAGAWA, 舟橋政司, EXPERIMENTAL INVESTIGATION OF AIR VOID FORMED AROUND STEEL BAR USING X-RAY CT SCANNING, Proceedings of the Seventh International Conference on Concrete under Severe Conditions - Environment and Loading, Volume 1, 742-748, 2013.09, Corrosion of Steel bar is affected by several factors such as chloride ion concentration, oxygen and water supply. Interfacial zone between concrete and steel bar is also important factor on steel corrosion. It is well known that air void formed around steel bar accelerates corrosion, however air void structure such as size and distribution were not fully understood. This study presents the observation results of three dimensional structure of air void around steel bar obtained by X-ray CT (Computed Tomography) scanning. Mortar specimens with height of 500mm and cross section of 150×150mm are prepared. Water to cement ratio of mortars are varied 3 types to change bleeding ratio. Aluminum bar are used as alternative material for steel bar because X-ray can not transmit in steel. Two bars with different height, 30mm from top and bottom, are embedded in each specimen. One month after casting, observation using X-ray CT scanning is carried out. As a result, 2~5mm of thickness of air void is formed around top bar. On the other hands, the average thickness of air void around bottom bar is 0.1~0.3mm. However, several air voids with mm-ordered size are detected on bottom bar which can cause macro-cell corrosion. Air void size around top bar depended on water to cement ratio, larger void is formed in specimen with higher water to cement ratio. Using X-ray CT scanning is effective to evaluate air void structure quantitatively..
62. Hiroshi Yokota, Hidenori Hamada, Mitsuyasu Iwanami, Evaluation and prediction on performance degradation of marine concrete structures, Proceedings of Third International Conference on Sustainable Construction Materials and Technologies - SCMT3, 2013.08, Typical deterioration of concrete structures in marine environments is chloride-induced
corrosion of rebar. After starting corrosion, it progresses rapidly and loss in structural
performance or even structural collapse may be consequences. To meet these facts, it is
extremely important to coordinate durability design and strategic maintenance and essential
to establish life-cycle management strategies. The authors have been conducting several
research programs for the core parts of the life cycle management system of marine concrete
structures. In this paper, the results and discussions are introduced how deterioration of
concrete members and structural performance degradation should be evaluated and assessed.
In addition, the effect of marine fouling organisms attaching the surface of concrete is
experimentally discussed. Finally, prediction with the Markov-chain is proposed in the
life-cycle management. Some of the practical considerations have been introduced in the
design and maintenance standards for port and harbor structures..
63. Rita Irmawaty, Daisuke Yamamoto, Hidenori Hamada, Yasutaka SAGAWA, Deterioration of Prestressed Concrete Beams Due to Combined Effects of Carbonation and Chloride Attack, Proceedings of Third International Conference on Sustainable Construction Materials and Technologies - SCMT3, 2013.08, Performance of prestressed concrete (PC) beams subjected to both carbonation and chloride ingress has not been clarified well so far. This paper presents the evaluation results and discussion on materials deterioration and corrosion state of prestressing wire/tendons of 35 year’s test PC beams. All beams were exposed to the actual marine tidal environments at the Sakata Port more than 20 years, then transferred and stored in a constant temperature over 15 years. The results indicated that all beams showed deterioration on the exterior and the whole surface of beams was carbonated. Even carbonation did not cause corrosion of reinforcement, however, it may have contributed to degradation of cover concrete. In addition, even though tendons were protected by sheath and mortar grouting, however, corrosion area on tendons
reached 40%, and prestressing wires corrosion length was 50 to 73%, indicating severe corrosion conditions for PC beams with 30 mm cover depth..
64. Toru Yamaji, Yoshikazu Akira, Hidenori Hamada, Kazuo Yamada, Study on concrete deterioration and deterioration indicators in marine environments, Proceedings of Third International Conference on Sustainable Construction Materials and Technologies - SCMT3, 2013.08, In order to investigate the deterioration of concrete in marine environments, both concrete cores sampled from existing structures and test specimens exposed in an outdoor pool of natural seawater are used. These specimens were examined using the Vickers hardness test and EPMA (Electron Prove Micro Analyzer). The following behaviors were observed:
1) The penetration depth of Mg2+ was correlated with both the neutralization depth and the depth of SO4
2- penetration.
2) Deteriorated areas in concrete specimens determined by Vickers hardness were correlated with the penetration depth of Mg2+. One reason for this deterioration is considered to be the phase change of C-S-H (Calcium silicate hydrate) to M-S-H (Magnesium silicate hydrate), which has a lower strength than C-S-H.
3) The penetration depth of Mg2+ can be an indicator of concrete deterioration progress in marine environments..
65. Mohammed Tarek Uddin, Hidenori Hamada, Mohammed Abdullah Al Mamun, Ariful Hasnat, Corrosion of cement paste coated steel bars in marine environment, Proceedings of Third International Conference on Sustainable Construction Materials and Technologies - SCMT3, 2013.08, A detailed experimental investigation was carried out to understand the performance of different cement paste coated steel bars against chloride-induced corrosion. Cylinder concrete specimens of diameter 100 mm and height 200 mm were made with steel bars embedded in concrete at a cover depth of 20 mm. Twenty-two separate cases were made with and without cement paste coated steel bars. W/C ratio of cement paste was varied from 0.3 to 1.0. After curing for one-month, the specimens were exposed to an accelerated chloride-induced corrosion environment. Each cycle of exposure consists 3.5 days under seawater exposure at 60oc and 3.5 days drying under atmospheric exposure. The specimens were tested after 10, 20, and 45 cycles of exposure. The test items include compressive strength of concrete, chloride ingress into concrete (acid soluble and water soluble chloride content), electrochemical evaluation of corrosion (half cell potential, polarization resistance of steel bars, concrete resistance, and anodic polarization curves), microscope investigations of steel-concrete interface, and physical evaluation of corrosion (corroded area, pit depth, weight loss) over the steel bars.
Based on this investigation, it is revealed that time to initiate corrosion is significantly increased for cement paste coated steel bars, particularly for coating with a low W/C. It is understood that chloride threshold limit for initiation of corrosion over the steel bars is significantly influenced by the nature of the steel-concrete interface around steel bars. The relationship between water soluble chloride content in concrete and acid soluble chloride content in concrete is also proposed..
66. Amry Dasar, Hidenori Hamada, Yasutaka SAGAWA, Takanori IKEDA, Durability of marine concrete with mineral admixture and marine aquatic organism layer, Proceedings of Third International Conference on Sustainable Construction Materials and Technologies - SCMT3, 2013.08, The high chloride ion concentration along with the presence of oxygen and water leads to accelerated corrosion process. It is fact that, durability of marine concrete depends corrosion resistance of concrete. On the other hand, addition of mineral admixture and covered marine aquatic organism layer has a potential to reduce the risk of corrosion. A total of 6 samples were prepared which had been exposed in the marine environment for 13 years. During the initial several years, marine aquatic organism layer was formed. In order to investigate the effect of mineral admixture and marine aquatic organism layer against corrosion, experimental laboratory study was carried out to measure corrosion potential and micro-pore structures related to the rate of chloride ion diffusion. Results show that mineral admixture can reduce the risk of corrosion. Moreover, marine aquatic organism layer had a positive effect to prevent the chloride ingress into concrete..
67. Yoshikazu Akira, Kazuhiro Masuda, Toru Yamaji, Hidenori Hamada, Study on durability and corrosion protection performance of concrete cover method for port steel pipe structures, Proceedings of Third International Conference on Sustainable Construction Materials and Technologies - SCMT3, 2013.08, Researching on corrosion protection technologies for steel pipe piles have been under operation by the exposure test using real pier in HASAKI since 1984. This paper is reporting the durability and corrosion protection performance of concrete cover method obtained from the exposure test. Deterioration of concrete cover was differed by materials and environments. Concrete cover in splash zone and marine atmospheric zone after 25 years was spalled off and fracture of reinforcing bar due to corrosion was occurred. On the other hand, concrete cover in tidal zone was sound. Despite the chloride ion concentration at steel surface in concrete was about 20 kg/m3, steel had not been corroded. It is considered that diffusion of oxygen into the concrete was limited to the level that could not generate the steel corrosion..
68. Daisuke Yamamoto, Hidenori Hamada, Yasutaka SAGAWA, Toshiumi Hiromitsu, Evaluation of compressive strength of concrete using small diameter core, Proceedings of Third International Conference on Sustainable Construction Materials and Technologies - SCMT3, 2013.08, In Japan, large number of concrete structures were constructed in the high economic growth period (60’s~70’s), and they are entering a period over the designed service life, therefore the proper life cycle management for life extension of these structures is becoming necessary. The use of small diameter core specimen for compressive strength test in conducting
the maintenance procedures for existing structures is desirable technology because it gives minor damage to the structure and less risk to cut off reinforcements when the core sampling is done. However, it is known that the variance of compressive strength test result by a small diameter core becomes large and it is difficult to evaluate precisely the compressive strength. From this background, the research described in this paper focused on development of the compressive strength test method by using small diameter core..
69. 山本大介, 廣光俊海, 濵田 秀則, 佐川 康貴, 小径コアの圧縮強度の変動に関する基礎的研究, コンクリート工学年次論文集,Vol.35,No.1,2013、p.403-408, 35巻, 1号, 403-408, 2013.07, 本研究では,一般的に圧縮強度のばらつきが大きい小径コアを用いた試験方法を向上させることを目的に,コンクリートおよびモルタル平板から小径コアを採取し,圧縮強度試験を行った。その結果,1)小径コアの圧縮強度のばらつきの大きな要因は供試体個々の骨材の内部構成のばらつきにあること,2)安定した小径コアの圧縮強度を求めるために必要な供試体本数は11本以上であり,その際小径コアの圧縮強度はφ100mmコアに比べて85~87%となることがわかった。.
70. 烏田 慎也, 佐川 康貴, 山時 翔, 濵田 秀則, 電気泳動法の実効拡散係数と浸漬法の見掛けの拡散係数との関係に関する実験的考察, コンクリート工学年次論文集,Vol.35,No.1,2013、p.859-864, 35巻, 1号, 859-864, 2013.07, 本研究は,塩化物イオン拡散係数のさらなる精度の高い換算方法を考察するために,電気泳動試験および浸漬期間を3 ヶ月,6 ヶ月,9 ヶ月,12 ヶ月とした3%塩水浸漬試験を行った。その結果,電気泳動法における非定常期間が配合毎に異なること,見掛けの拡散係数が時間依存性を有するパラメータであることが分かった。また,今後のデータの蓄積により,土木学会規準に示された換算係数k1k2 に電気泳動法における非定常期間を一つのパラメータとした補正を行うことで,配合等その他要因を考慮した精度の高い換算係数が得られる可能性を見出すことができた。.
71. 佐川 康貴, 畠山 繁忠, 濵田 秀則, 今村 壮宏, 高濃度NaClにより乾湿繰返し作用を受けたコンクリートの塩分浸透性状, コンクリート工学年次論文集,Vol.35,No.1,2013, 35巻, 1号, 865-870, 2013.07, 本論文では,凍結防止剤に由来する高濃度の塩化物イオンを含む漏水によるコンクリート橋の塩害を想定し,室内実験において飽和NaCl を用いた浸漬試験を行い,コンクリートへの塩分浸透性状の検討を行った。また,凍結防止剤が散布される4 か所のコンクリート橋の桁端部において曝露試験を行った。その結果,室内実験では水セメント比が高いと乾湿繰返しよりも連続浸漬の方が多く塩化物イオンが浸透した。また,曝露試験では,表面の塩分濃度が低下する傾向が確認され,曝露環境によっては試験後1 年程度で浸透面から深さ50mm の位置において,1.8kg/m3 の高い塩化物イオン濃度を示した。.
72. Amry DASAR, 濵田 秀則, 佐川 康貴, Rita Irmawaty, Corrosion Evaluation of Reinforcing Bar in Sea Water Mixed Mortar by Electro-chemical Method, コンクリート工学年次論文集,Vol.35,No.1,2013, 35巻, 1号, 889-894, 2013.07, Sea water has a potential to be utilize as mixing water. However, sea water contains high chloride ion concentration which can lead to accelerated corrosion of reinforcement. In order to investigate the effect of sea water as mixing water and partial replacement of cement by Blast Furnace Slag (BFS) on corrosion rate of reinforcement, electrochemical testing such as half-cell potential and polarization curve were conducted. The results show that sea water mixing enhanced the corrosion risk of reinforcement. However, partial replacement of cement by BFS can reduce the risk of corrosion..
73. 濵田秀則, 佐川康貴, 池田隆徳, 多田昂平, モルタル中の塩分含有量と埋設鉄筋の不動態の状態の関係に関する実験的考察, セメント・コンクリート論文集, 66, 466-471, 2013.02.
74. 秋山哲治, 鈴木亮, 鈴木達也, 濵田秀則, フィルム材を用いた型枠がコンクリート表層の耐久性向上に及ぼす効果に関する検討, セメント・コンクリート論文集, 66, 507-514, 2013.02.
75. 山本大介, 佐川康貴, 濵田秀則, 今村壮宏, 内在塩分を含むコンクリート部材の断面修復工法による補修効果および再劣化抑制に関する実験的考察, コンクリート構造物の補修、補強、アップグレード論文報告集、第12巻、2012.11, 第12, 101-108, 2012.11.
76. 松下博通, 山本大介, 濵田秀則, コンクリート製下水道管渠劣化診断フローの提案, 下水道協会誌, 49巻, 597号, 106-113, 2012.07.
77. Rita Irmawaty, 山本大介, 濵田秀則, 佐川康貴, Performances of PC Sheet Pile after 12years Exposure in the Marine Tidal Environments, コンクリート工学年次論文集,Vol.34,No.1,2012, 34巻, 1号, 706-711, 2012.07, Performances of PC sheet piles were evaluated after 12 years exposure in the marine tidal environment. An evaluation of mechanical properties, carbonation depth, porosity, chloride content and PC steel condition were carried out. Overall, all specimens showed satisfactory performance: only a few concrete corner and edge chips, low chloride content and low rate of corrosion were observed. Investigation results indicated that BS5 (B = GGBFS, S = steam curing, and cover thickness of 5 cm) showed the best performance (more durable) although its strength was lower than the other..
78. 審良善和, 山路徹, 小林浩之, 濵田秀則, 練混ぜ水に海水を用いたコンクリートの干満帯における長期耐久性, コンクリート工学年次論文集,Vol.34,No.1,2012, 34巻, 1号, 820-825, 2012.07, 本研究は,練混ぜ水に海水を用いたコンクリートの干満帯における長期耐久性を評価するために,干満帯に26 年間暴露した供試体を用い,圧縮強度,塩化物イオン濃度分布および鉄筋腐食について検討を行った。暴露26 年までの結果では,いずれのコンクリートも材齢28 日の圧縮強度を大きく下回るものはなく,初期と同程度またはそれ以上の状態を保持していると考えられた。また,干満帯のような外来塩化物イオンの浸透量が大きく,また,コンクリートが高飽水率になる環境下にある鉄筋の腐食は,練混ぜ水に海水を用いた場合も,水道水を用いた場合と大きな差はないと考えられた。.
79. Hidenori Hamada, Yasutaka Sagawa, Daisuke Yamamoto, Some Studies on Performance Enhancement of Recycled Aggregate Concrete --2009-2011 in Japan --, Proceeedings of the 2nd UAP/SEL Seminar on Recycling of Demolished Concrete, 1-10, 2011.12.
80. Toru Yamaji, Yoshikazu Akira, Tsutomu Fukute, Hidenori Hamada, Masanori Ito, Kenji Hayakawa, Studies on Applicability of Recycled Aggregate Concrete to Marine Environments in Port and Airport Research Institute, Proceedings of the 2nd UAP/SEL Seminar on Recycling of Demolished Concrete, 11-24, 2011.12.
81. Yoshikazu Akira, Toru Yamaji, Hidenori Hamada, Tsutomu Fukute, Masanori Ito, Kenji Hayakawa, Penetration Property of Chloride Ion into Recycled Concrete, Proceedings of the 2nd UAP/SEL Seminar on Recycling of Demolished Concrete, 25-37, 2011.12.
82. 山路徹, 審良善和, 小林浩之, 濵田秀則, 海洋環境下における高炉およびフライアッシュセメントを用いたコンクリートの長期耐久性, 混和材の積極利用のためのシンポジウム論文集, 133-138, 2011.12.
83. 佐川康貴, 山時翔, 濵田秀則, 高炉スラグ微粉末混和コンクリートの塩化物イオン実効拡散係数に関する研究, 混和材の積極利用のためのシンポジウム論文集, 2011.12.
84. 山路徹, 審良善和, 小林浩之, 濵田秀則, 海洋環境下でのコンクリートの化学的侵食による劣化に及ぼす暴露環境の影響, コンクリート構造物の補修、補強、アップグレード論文報告集, 第11巻, 550ページ, 25頁~30頁, 2011.10.
85. 山本大介, 廣光俊海, 濵田秀則, 佐川康貴, 小径コアによる圧縮強度試験値の変動に関する実験的考察, コンクリート構造物の補修、補強、アップグレード論文報告集, 第11巻, 550ページ, 313頁~320頁, 2011.10.
86. 櫨原弘貴, 武若耕司, 山口明伸, 添田政司, 濵田秀則, けい酸塩系表面含浸材の表層品質改善効果が透気係数に与える影響に関する研究, コンクリート構造物の補修、補強、アップグレード論文報告集, 第11巻, 550ページ, 329頁~336頁, 2011.10.
87. 林亮太, 櫨原弘貴, 武若耕司, 山口明伸, 濵田秀則, けい酸塩系表面含浸材の施工状態評価に用いる現場試験方法に関する研究, コンクリート構造物の補修、補強、アップグレード論文報告集, 第11巻, 550ページ, 343頁~348頁, 2011.10.
88. Hidenori Hamada, Yasutaka sagawa, Toru Yamaji, Anti-Corrosion Technologies on Bridges Affected by Marine Environment, Proceedings of the 2011 International Forum on Bridge Engineering, Taipei, Taiwan, September 8-9, 2011, 81-102, 2011.09.
89. Rita Irmawaty, Hidenori HAMADA, Yasutaka SAGAWA, Sho Yamatoki, A DISCUSSION ON DURABILITY OF HIGH STRENGTH CONCRETE (HSC) IN VIEW POINT OF MICRO PORE STRUCTURE, Proceedings of The 3rd International Conference of European Asian Civil Engineering Forum, Yogyakarta, 20-22 September 2011, S-49 - S-54, 2011.09.
90. 小林浩之, 審良善和, 山路徹, 濵田秀則, 若林徹, 望月紀保, 鉄筋表面の環境改善を考慮したコンクリート中鉄筋のカソード防食設計について, 材料と環境討論会講演集, 58巻, 217-220, 2011.09.
91. 山路徹, 審良善和, 濱田秀則, 海洋環境下におけるコンクリートひび割れ部での腐食挙動, コンクリート工学年次論文集, 33, 1, 857-862, 2011.07.
92. 濵田秀則, 佐川康貴, 井上祐一郎, 林建祐, 堆積岩を粗骨材として用いたコンクリート構造物のASR による劣化事例, コンクリート工学年次論文集, 33, 1, 1073-1078, 2011.07.
93. 池田隆徳, 濱田秀則, 佐川康貴, 多田昂平, 鉄筋周囲に形成される空隙のX線CTスキャナによる定量評価, コンクリート工学年次論文集, 33, 1, 1085-1090, 2011.07.
94. 佐川康貴, 真壁央稔, 濱田秀則, 池田隆徳, 骨材中の水分が再生骨材コンクリートの強度に及ぼす影響に関する研究, コンクリート工学年次論文集, 33, 1, 1529-1534, 2011.07.
95. 松下博通、 山本大介、 関野勇, コンクリート製下水道管渠の劣化調査方法に関する検討, 下水道協会誌、 社団法人日本下水道協会, 第47巻, 578号, 120-127, 2010.12.
96. 平安山良和, 濵田秀則, 佐川康貴, 鈴木雅博, 高炉スラグ微粉末6000を使用したコンクリートの収縮特性に関する実験的研究, 土木構造・材料論文集, 第26号, 32, CD-ROM, 2010.12.
97. Toru Yamaji, Yoshikazu Akira, and Hidenori Hamada, Effect of Exposure Environment and Period on Chloride Diffusion in Concrete with Inhibitor., Advances in Concrete Structural Durability. (Proceedings of the 2nd International Conference on Durability of Concrete Structures ICDCS2010), 311-319, 2010.11.
98. Mingdi Gao, Hidenori Hamada, Yasutaka Sagawa, and Takanori Ikeda, Evaluation on Chloride Diffussion Coefficient of Blast - Furnace Slag Cement Concrete., Advances in Concrete Structural Durability (Proceedings of the 2nd International Conference on Durability of Concrete Structures ICDCS2010), 243-248, 2010.11.
99. Takanori Ikeda, Yuichiro kawabata, Hidenori Hamada, and Kazuo Yamada, Mitigating effect of Fly Ash on the ASR-related Exposure of Mortar Using Reactive Aggregate at the Pessimum Proportion., Advance in Concrete Structural Durability (Proceedings of the 2nd International Conference on Durability of Concrete Structures ICDCS2010), 473-481, 2010.11.
100. Daisuke Yamamoto, Hiromichi Matsushita, Isamu Sekino, and Hidenori Hamada, Detailed Investigation of 38 Year Old Concrete Sewerage Pipes Deteriorated by Sulphuric Acid Attack., Advances in Concrete Structural Durability (Proceedings of the 2nd International Conference on Durability of Concrete Structures ICDCS2010), 557-565, 2010.11.
101. 松下博通、 山本大介、 関野勇, 38年間供用されたコンクリート製下水道管渠の劣化状況について, 下水道協会誌、 社団法人日本下水道協会, 第47巻, 576号, 149-155, 2010.10.
102. 池田隆徳, 濵田秀則, 佐川康貴, 山田一夫, 骨材からのアルカリ溶出性状とASRによる膨張に対する影響の評価, コンクリート工学年次論文集、Vol.32、No.1、2010, 32, 1, 917-922, 2010.06.
103. 井上祐一郎, 濵田秀則, 川端雄一郎, 山田一夫, ペシマム現象を生じる骨材を用いたモルタルのフライアッシュによるASR抑制効果, コンクリート工学論文集、Vol.32、No.1、2010, 32巻, 1号, 953-958, 2010.06.
104. 濵田秀則, 森川亮太, 佐川康貴, 池田隆徳, 数種の条件の違いがモルタル中鉄筋の電気化学的計測結果に及ぼす影響, コンクリート工学年次論文集、Vol.32、No.1、2010, 32巻, 1号, 1085-1089, 2010.06.
105. 山路徹, 濵田秀則, 水間誠治, 山本俊彦, 海洋環境下におけるステンレス鉄筋の耐食性に関する研究, 土木学会論文集E、 Vol.66, No.2, pp.207-220, 66巻, 2号, 207-220, 2010.06.
106. Hidenori Hamada, Yasutaka sagawa, Takanori Ikeda, Ryota Morikawa, Sevaral factors affecting the anodic polarization curve of steel bars embedded in mortar, Proceedings of the 6th International Conference on Concrete under Severe Conditions (CONSEC'10), Vol.1, 201-208, 2010.06.
107. 審良善和, 濵田秀則, 山路徹, 中野松二, 岩波光保, 産業副産物を有効活用したコンクリートの海洋構造物への適用に関する研究, 海洋開発論文集、 第26巻、 1035-1040頁, 26巻, 1035-1040, 2010.06.
108. 山路徹, 審良善和, 濵田秀則, 山田一夫, 海洋環境におけるコンクリートの劣化性状および劣化指標に関する検討, 土木学会論文集E, 66巻, 1号, 21~37頁, 2010.02.
109. 濵田秀則, 佐川康貴, 森川亮太, 高橋勝也, 鉄筋周囲に発生する空隙と鉄筋腐食の関係に関する実験的考察, セメント・コンクリート論文集, No.63, 428 - 433, 2010.02.
110. Hidenori Hamada, Shin Tanikawa, R. N. Swamy, The Role of Polymer Surface Coating in Sustainable Structural Rehabilitation of ASR affected RC Beams, Proceedings of 13th International Congress on Polymer in Concrete, 533-541, 2010.02.
111. 中井将博, 荒井信章, 濵田ヒデノリ, PCaPC部材と場所打ち部との剛結合の力学的性能に関する基礎的研究, コンクリート工学論文集, 21巻, 1号, 13~24頁, 2010.01.
112. 佐川康貴, 森川亮太, 濵田秀則, 断面補修を行ったRC橋の塩害環境下における鋼材腐食に関する考察, コンクリート構造物の補修、補強、アップグレード論文報告集, 第9巻, 97~102頁, 2009.10.
113. 山路徹, 濵田秀則, 審良善和, 異なる海洋環境下および暴露期間における塩化物イオン拡散性状, コンクリート工学年次論文集, 31巻, 1号, 1003~1008頁, 2009.07.
114. 西政好, 濵田秀則, 佐川康貴, 川端雄一郎, フライアッシュ混和コンクリートのASRによる膨張挙動に関する研究, コンクリート工学年次論文集, 31巻, 1号, 1327~1331頁, 2009.07.
115. 山本大介, 佐川康貴, 濵田秀則, 松下博通, 超音波法による硫酸劣化深さの推定手法に関する検討, コンクリート工学年次論文集, 31巻, 1号, 2137~2142頁, 2009.07.
116. 伊予田岳史, 檀康弘, 川端雄一郎, 濵田秀則, 高炉コンクリートの耐久性における養生敏感性, コンクリート工学年次論文集, Vol.30, No.1, p.111-116, 2008.07.
117. 池田隆徳, 川端雄一郎, 濵田秀則, 佐川康貴, 混和材による高温養生を行ったモルタルのDEF膨張の抑制効果, コンクリート工学年次論文集, Vol.30, No.1, p.135-140, 2008.07.
118. 尾上幸造, 松下博通, 濵田秀則, 佐川康貴, コンクリートの静的圧縮破壊過程に関するエネルギー的考察, コンクリート工学年次論文集, Vol.30, No.1, 2008.07.
119. 山路徹, 中野松ニ, 濵田秀則, 山田一夫, 実海洋環境下に長期間暴露されたコンクリートの諸特性に関する調査結果, コンクリート工学年次論文集, Vol.30, No.1, 2008.07.
120. 審良善和 山路徹 濵田秀則, 産業副産物(製鋼スラグ・フライアッシュ・高炉スラグ)を有効利用したコンクリートの品質および耐久性に関する研究, 港湾空港技術研究所報告 第47巻 第2号, 第47巻 第2号, 2008.06.
121. 山路徹, 横田弘, 中野松ニ, 濱田秀則, 実構造物調査および長期暴露試験結果に基づい港湾RC構造物における鉄筋腐食照査手法に関する検討, 土木学会論文集, 土木学会論文集E、 Vol.64、No.2、335-347, 2008.05.
122. 審良善和, 堀井秀之, 濵田秀則, 山路徹, 産業副産物系骨材を使用した硫黄固化体の耐海水性に関する基礎的研究, 港湾空港技術研究所資料 (独立行政法人港湾空港技術研究所発刊), No.1166, 2007.12.
123. 佐川康貴, 松下博通, 濵田秀則, 宮本能久, 守永裕美, 橋梁資産価値評価に基づいたインフラ整備のあり方に関する一考察 --福岡市の試算結果を事例として--, 第51回日本学術会議材料工学連合講演会 講演論文集, 97~98ページ, 2007.11.
124. 堀井秀之, 審良善和, 濵田秀則, 産業副産物系骨材を使用した硫黄固化体の耐海水性に関する基礎的研究, コンクリート工学年次論文集, Vol.29、No.2、2007, 2007.07.
125. 川端雄一郎, 山田一夫, 松下博通, 濵田秀則, 安山岩骨材の岩石学的評価とASR膨張挙動の解析, コンクリート工学年次論文集, Vol.29, No.1, pp.1221-1226, 2007.07.
126. 高橋良輔, 濵田秀則, 鉄鋼スラグ水和固化体の空港舗装適用へ向けた基礎物性の検討, 独立行政法人港湾空港技術研究所 港湾空港技研資料, No.1153, 2007.06.
127. Mitsuyasu IAWANAMI, Toru YAMAJI, Hiroshi YOKOTA and Hidenori HAMADA, Effect of surface-attaching marine organisms on deterioration of concrete structures, Proceedings of the International Workshop on Life Cycle Management of Coastal Concrete Structures, Nagaoka, Japan, Nov. 2006, Edited by Yokota and Shimomura, pp.23-30, 2006.11.
128. Hidenori HAMADA, Hiroshi YOKOTA, Toru YAMAJI and Tarek Uddin Mohammed, Long-term exposure test of concrete materials under marine environmnts carried out by PARI, Proceedings of the International Workshop on Life Cycle Management of Coastal Concrete Structures, Nagaoka, Japan, Nov. 2006, Edited by Yokota and Shimomura, pp.31-36, 2006.11.
129. Tarek Uddin MOHAMMED and Hidenori HAMADA, Corrosion of steel bars in cracked concrete at the early age of exposure, Proceedings of the International Workshop on Life Cycle Management of Coastal Concrete Structures, Nagaoka, Japan, Nov. 2006, Edited by Yokota and Shimomura, pp.115-126, 2006.11.
130. Yoshikazu AKIRA, Toru YAMAJI, Hiroshi YOKOTA, Hidekazu HORII, Hidenori HAMADA and Tarek Uddin MOHAMMED, Influence of the pore of the steel-concrete interface on the corrosion of steel bars due to chloride attack, Proceedings of the International Workshop on Life Cycle Management of Coastal Concrete Structures, Nagaoka, Japan, Nov. 2006, Edited by Yokota and Shimomura, pp.145-150, 2006.11.
131. Toru YAMAJI and Hidenori HAMADA, Long-term durability of concrete with surface coating materials under marine environment, Proceedings of the International Workshop on Life Cycle Management of Coastal Concrete Structures, Nagaoka, Japan, Nov. 2006, Edited by Yokota and Shimomura, pp.209-216, 2006.11.
132. 高橋良輔, 堀井秀之, 松永久宏, 濵田秀則, 海洋構造物へ適用可能な副産物系固化体の開発, 豊かな沿岸を造る生態系コンクリート -磯焼けを防ぎ藻場を造る- 第Ⅱ編シンポジウム論文集, 土木学会技術シリーズ72号、pp.152-157, 2006.11.
133. Ryosuke Takahashi, Hidenori Hamada, Mechanical Property of Steel-making Slag Concrete with Japanese Specified Strength of An Airport Concrete Pavement, Proceedings of 2nd Asian Concrete Federation Conference, pp.CMT-16 - CMT 23, 2006.11.
134. Yoshikazu Akira, Hidenori Hamada, Toru Yamaji, Nguyen Nam Thang, Experimental Study on Durability of Port RC Structure in Southeast Asian Countries in Marine Environment, Proceedings of 2nd Asian Concrete Federation Conference, pp.DCS-30-DCS-39, 2006.11.
135. 山路徹, 中野松二, 濵田秀則, 港湾RC構造物における塩化物イオン拡散係数調査結果および簡易推定手法に関する検討, 独立行政法人港湾空港技術研究所 港湾空港技術研究所資料, No.1141、2006.6、31頁, 2006.09.
136. Tarek Uddin Mohammed and Hidenori Hamada, Corrosion of Horizontal Bars in Concrete and Method to Delay Early Corrosion, ACI Materials Journal, A Journal of The American Concrete Institute, Vol.103, No.5,pp.303-311, 2006.09, [URL].
137. 尾上幸造, 松下博通, 濵田秀則, 佐川康貴, 圧縮力を受けるコンクリート内部の微細ひび割れ発生伝播に関するエネルギー的考察, コンクリート工学年次論文集, Vol.28、No.1、pp.491-496, 2006.07.
138. 高橋良輔, 濵田秀則, 曲げ強度5N/mm2クラスの鉄鋼スラグ水和固化体の力学特性, コンクリート工学年次論文集, Vol.28、No.1、pp.1613-1618, 2006.07.
139. Tarek Uddin Mohammed and Hidenori Hamada, Corrosion of Steel Bars in Concrete with VArious Steel Surface Conditions, ACI MAterials Journal, Vol. 103, No.4, pp.233-242, 2006.07.
140. 宮田義一, 若林徹, 濵田秀則, 耐海水ステンレス鋼ライニングを施した海洋鋼構造物の電気防食特性, 独立行政法人港湾空港技術研究所報告, 第45巻、第2号、pp.169-196, 2006.06.
141. 宮田義一, 阿部正美, 濵田秀則, 清水一夫, 中野啓眞, 芥川博昭, 鋼管杭の防食工法に関する現地試験(20年目の中間報告), 独立行政法人港湾空港技術研究所 港湾空港技術研究所資料, No.1123、2006.6、141頁, 2006.06.
142. 濵田秀則, 堀井秀之, 審良善和, 数種類の骨材を用いた硫黄固化体の材料特性, 独立行政法人港湾空港技術研究所 港湾空港技術研究所資料, No.1129,p.1-35, 2006.06.
143. 濵田秀則,兼坂薫,鈴木靖庸,宮田義一, 鋼材における電着および電気防食併用工法の防食性能に関する実験的検討, 港湾空港技術研究所 資料 1113, 1113, 2005.12, [URL], 港湾鋼構造物の海中部における腐食対策として一般的に電気防食法が適用されている.港湾鋼構造物へ電気防食法を適用した場合,副生成物として鋼材表面上に電着被膜が析出し,電気防食における所要防食電流密度が低減される効果が確認されている.また,最近ではこの電着被膜を外部電源により強制的に生成させ,電着被膜により防食を図る工法が,“電着工法”として既に開発されている.この電着工法により最大限の防食効果を得るためには,電着被膜を一定の厚膜とする必要があるため施工期間が長期化すること,電着被膜が剥離した場合に自己修復効果がないこと等から,広く適用されるには至っていない.そこで港湾鋼構造物の新しい防食法の試みとして,電着と電気防食を併用して適用することを考えた.本研究では,「初期に外部電源により電着被膜を生成させ,その後電気防食を適用する併用工法」の防食効果を把握するための一連の実験的検討を行った.得られた結果の概要を以下に示す.
(1)室内試験結果より電気防食の必要電流密度を低減させるために必要な電着被膜の必要最小膜厚は約100μmであることがわかった.また,電気防食における所要防食電流密度は通常の電気防食法と比較して最大で95%も低減可能であることがわかった.
(2)海水循環水槽による実環境模擬試験結果より,各環境での所要防食電流密度は,電気防食法と比較して,H.W.L.では約80%,H.W.L.以深では最大で95%低減可能であることが確認された.また;電着被膜を生成させることで電気防食法単独では適用が難しいとされている干満帯上部への適用の可能性も確認された.
(3)鋼管杭の海中部を対象とした試験施工より,施工5ヶ月後の調査では外観上腐食は認められず,電位も防食電位を満たしていることから良好な防食状態であることが確認された.また,電気防食における所要防食電流密度が大幅に低減されることが推定され,実環境においても電着法と電気防食法の併用工法の有効性が確認された..
144. 濵田秀則,横田弘,菊池喜昭, 促進試験によるプレストレストコンクリート製矢板の海洋環境下における耐久性評価 , 港湾空港技術研究所 資料 1097, 1097, 2005.06, [URL], プレストレストコンクリート製矢板を本文では「PC矢板」と略記する.PC矢板は河川などの護岸用あるいは土留め壁,擁壁用としてこれまでに多く用いられている.しかし,港湾用の矢板としての使用実績は極めて少ない.その理由は,港湾環境は海洋環境であることから,コンクリート内部の鋼材腐食防止の観点から,矢板厚が大きくならざるを得ないためである.一方,矢板打ち込みの施工性を向上させるためには,矢板の厚さは可能な限り小さくすることが望ましい.これまでに,PC矢板が港湾工事においてあまり用いられていないのは,かぶり厚さを適切に定めるための知見が十分に得られていないことが一つの大きな理由である.そこで本研究は,鋼材の腐食環境である港湾環境においてPC矢板を用いる場合に,適切と考えられるかぶり厚さを設定するための知見を得ることを目的としている.本研究では,供試体を用いた劣化促進試験を実施し,海洋腐食環境下におけるPC矢板の劣化挙動を調べた.その結果に基づき,PC矢板の海洋腐食環境下における耐久性を評価し,適切なかぶり厚さに対する考察を行った.得られた主要な結論は以下のとおりである.
(1)劣化促進試験の前後でコンクリート自体の強度,弾性係数の物性値に低下の傾向が見られないことから,コンクリート自体の耐久性は優れていると判断される.
(2)PC矢板に用いられる設計強度(70N/mm2)相当のコンクリートであれば,コンクリート中への塩分の浸透はかなり抑制することが可能である.
(3)蒸気養生と湿潤養生を行った供試体の試験結果に明確な差が見られないことより,蒸気養生がコンクリートの品質低下を招くことはないと確認できた.
(4)耐久性を考慮してかぶり厚を考察すると,内部鋼材の腐食開始時が20年で30mm,30年で40mm,50年で50mmが一応の目安となる..
145. 濵田秀則,山路徹, コンクリート構造物のモニタリングへの光ファイバの適用に関する基礎的研究, 港湾空港技術研究所 資料 1092, 1092, 2004.12, [URL], 社会基盤施設は,一般には50年以上にも及ぶ長期間の耐用年数を設定して建設がなされる.近年の我が国における高齢化社会への移行状況を考えた場合,既存の施設に対してさらに長期の耐用年数が要求されることも十分に予想される.しかし,あらゆる構造物は供用の開始とともに徐々に劣化・老巧化が進行し,そのために構造物の信頼性も徐々にではあるが低下していく.劣化・老朽化が軽微なうちに適切な補修対策を講じることは社会的・経済的に極めて重要であり,このことから構造物の挙動を的確にモニタリングし評価する技術の開発に対する要請が近年一段と強まっている.
 本研究においては,センシング材料として高い可能性を有する光ファイバに着目し,コンクリート構造物のモニタニングに対して光ファイバを適用していく技術を開発することを目的としている.光ファイバの応用方法として,“破断”,“曲げ損失”および“後方散乱”に関する情報を有効に利用するための実験的検討を実施した.本研究により以下に示すような結果を得ることができた.
1)光ファイバの力学的特性に関して知見を得ることができた.
2)光ファイバの破断を情報として利用する方法に関して,変状の動く方向と光ファイバのなす角度が重要となることを示し,光ファイバをひび割れとほぼ平行に貼付する方法を新たに提案できた.
3)光ファイバの透過光損失を情報として利用する方法について,幾つかの適用可能な方法を示すことができた.
4)光ファイバによるひずみ計測結果を情報として利用する方法について,光ファイバに予めプレテンションを与えておくことにより,精度のよい計測が可能となることを確認した.
5)今後の研究の方向性について,“フェールセーフ”という考え方に沿った方向性も有力であることを示した..
146. 小牟禮 建一,濵田秀則, 石垣空港における窒素酸化物の排出および濃度分布ならびに低減対策に関する調査, 港湾空港技術研究所 資料, 1083, 2004.06, [URL], 本研究では,最終的には空港から排出される窒素酸化物濃度の低減を目指し,空港内における窒素酸化物濃度の現状を把握する目的で,第三種空港である石垣空港において,滑走路周辺,エプロン周辺,ならびに空港近辺での窒素酸化物濃度の実態調査を行った.さらに,光触媒技術の適用による窒素酸化物濃度低減の可能性を模索するため,光触媒の一種である酸化チタンを用いた実験装置によって,空港周辺での窒素酸化物低減効果確認実験を行った.
 一連の調査・検討により,以下の知見を得た.
 1)空港内においては,航空機の挙動に関連した高濃度の窒素化物が検出され,空港が大きな窒素酸化物排出源となっていることがほぼ明らかとなった.
 2)エプロン,および滑走路の運用時間内において,エプロンでは運用時間中常時,滑走路上では航空機の離陸時に,瞬間的ではあるが非常に高い窒素酸化物濃度となる危険性が示唆された.
 3)窒素酸化物低減効果確認実験の結果から,酸化チタン混入塗料の効果が認められた.その低減効果は10%程度である.
 4)空港外では,空港の駐車場や船舶港などからも高濃度の窒素酸化物が検出され,低速で常時通過する自動車車輛,ならびに船舶の影響が大きいと推測された..
147. 山路徹,小牟禮建一,濵田秀則, 塩害環境下に15年間暴露されたコンクリートの耐久性および表面被覆材による塩害防止効果, 港湾空港技術研究所 報告, 43, 2, 73-109, 2004.06, [URL], 昭和50年代後半に那覇港の臨港道路に施工されたプレストレストコンクリート橋は,海上に位置し,厳しい塩害環境であるにもかかわらず,その設計・施工が道路橋の塩害対策に関する指針が改訂される前であったため,かぶりが3.5cm で施工されていた.そのため,塩害対策としてコンクリートに表面被覆を実施することが決定された.しかしながら,当時表面被覆材の選定基準などは明確ではなかったため,選定の際の基礎資料を収集することを目的として,コンクリート表面に異なる6種類の表面被覆を施した試験体の暴露試験が那覇港において1987年に開始された.本論文は,試験体暴露開始後15年時において,これらの表面被覆材の塩害防止効果を評価するため,被覆材外観,付着性,ひび割れ追従性,遮塩性等に関する各種試験を行い,その結果をまとめたものである.また,被覆を行っていないコンクリート試験体も現地に暴露し,コンクリートの耐久性に及ぼす水セメント比,鉄筋かぶりおよび暴露環境の影響に関する検討も行った.以上の検討より得られた知見を以下に示す.
 表面被覆を行っていないコンクリート試験体の場合,コンクリート中への塩化物イオンの浸透および鉄筋の腐食を抑制するためには,コンクリートの水セメント比を低減させることおよびかぶり厚さを増加させることが非常に有効であることが確認された.また,水セメント比や暴露環境等の違いによりコンクリートの酸素拡散性状が異なった場合,鉄筋の腐食速度は異なり,鉄筋表面における酸素供給量と鉄筋の腐食速度の間には良い相関が認められた.すなわち,コンクリートの酸素拡散性状を考慮することで,鉄筋の腐食速度が推定される可能性が示された.
 表面被覆を行ったコンクリート試験体の場合,表面被覆材の劣化状況は,その仕様によって大きく異なっていた.また,被覆材の付着性については,15 年後においても顕著な低下は見られなかった.しかしながら,表面に劣化が見られた被覆材においても,コンクリート中への塩化物イオンの浸透はほとんど無く,その結果として,コンクリート中の鉄筋は15 年後においても腐食していなかった.以上のことから,塩化物イオンが浸透していない段階において,コンクリートに適切な表面被覆を行うことは塩害対策として非常に有効であり,今回のような条件においては,15年間の長期においても塩害防止効果が十分に維持されることが確認された..
148. 濵田秀則,Tarek U.M.,山路徹,小牟禮建一, アルカリ骨材反応が発生したコンクリートに対する表面被覆の適用性に関する実験的検討, 港湾空港技術研究所 資料, 1050, 2003.06, [URL], アルカリ骨材反応(以後,本文においてはASRと称する)に関する問題は,我が国においても発生後既に30年程度が経過した.港湾構造物においても,約10数年前に実構造物における発生事例を報告した1).その後,ASRの問題は港湾分野のみならずコンクリート工学分野全体においても鎮静化した感がある.しかし,近年,新たにASRによる構造物の被害事例が報告されるに至り,その問題の重要性が改めて認識されてきた.すなわち,ASRの問題は必ずしも十分に解決されている訳ではないのである.
 本研究は,ASRが発生しているコンクリートに対して表面被覆を施した場合の反応抑制効果を検討したものである.本研究は以下の二つの項目で構成されている.一つは,表面被覆による無筋コンクリートの膨張抑制に関する実験であり,もう一つは,持続荷重下におけるRCはりおよびRC柱の内部応力に及ぼす表面被覆の効果に関する実験である.
 上記の二つのシリーズの実験結果を総合的に考察し,以下の結論を得ることができた.
 1)海中部,干満部あるいは波浪の影響を常時受ける飛沫郡のように,常にコンクリート表面が湿潤状態にあるような環境下においては,表面被覆によりASRの反応および膨張を十分に抑制することは困難である.
 2)異なる材料により構成される塗膜はその物性が各々異なるため,その効果を十分に得るためには,施工環境,暴露環境に適した材料の選定を行うことが極めて重要である.
 3)コンクリート表面が海水に接する環境であっても,海中部あるいは干満部のように常に湿潤状態にある環境以外の場合は,表面被覆によりASRの反応および膨張を抑制することは可能である.
 4)表面被覆の効果を最大限に得るためには,ASRの反応および膨張が開始される前に被覆を施すことが重要である.
 5)表面被覆を実施する隙には,コンクリート表面の一部でも開放部分が存在すると被覆の効果は大きく低下する..
149. Tarek Uddin MOHAMMED,濵田秀則,山路徹, Concrete Properties and Relationship Between Surface Strain and Strain Over the Steel Bars of ASR Affected Concrete Members , 港湾空港技術研究所 報告 042-02-06, 42, 2, 133-154, 2003.06, アルカリ骨材反応(ASR)が発生しているコンクリートにおいて生じている,コンクリート自身の物性,内部鉄筋およびコンクリート表面のひずみ,ひび割れの進展,鉄筋の機械的性質等の変化に関して詳細な実験的検討を行った.それに加えて,コンクリート中への塩化物イオンの拡散性状の試験,内部鉄筋の腐食状況の観察,SEMによるアルカリシリカゲルの観察,コンクリートの破断面におけるアルカリシリカゲルの観察を行った.実験には,寸法が250×250×600mmの角柱型の供試体,および直径が100mm,長さが200mmの円柱型の供試体を用いた.角柱型供託体には鉄筋コンクリート製と無筋コンクリート製の2種類があり,鉄筋コンクリート製の場合には,鉄筋量を数種に変えることにより,数種の異なる拘束状態に設定した.また,コンクリート中のアルカリ総量を等価Na2Oで6kg/m3になるように,練り混ぜ自にNaOHを加えている.供試体は,40℃に加熱した海水中に浸せきした.この状態で最長383日まで養生を行い,その間およびその後に各種の試験を実施した.
 コンクリート表面にひび割れが発生した直後,コンクリートの弾性係数は大幅な低下を示したが,その後はほぼ定常状態となった.コンクリートの圧縮強度の低下は,弾性係数の低下ほど顕著には生じなかった.内部鉄筋の有する拘束効果により,コンクリートの表面ひずみは抑制されていた.内部鉄筋の拘束率は,コンクリート表面のひずみおよび鉄筋のひずみに大きく影響していた.コンクリート表面のひずみと内部鉄筋のひずみには線形の関係が認められ,かつそれは鉄筋による拘束率が大きくなるほど相関性が高くなった.内部鉄筋がコンクリート表面に近いほどコンクリート表面のひずみは小さくなる傾向にあるが,鉄筋のひずみは大きくなる傾向にあった.コンクリート表面近傍に縦断方向の鉄筋を配置した場合は,横方向のコンクリート表面ひずみおよぴスターラップ鉄筋のひずみが大きくなった..
150. Tarek Uddin MOHAMMED,濵田秀則,山路徹, Long-term Durability of Concrete Made with Slag Cements under Marine Environments , 港湾空港技術研究所 報告 042-02-07, 42, 2, 155-192, 2003.06, 多くの海洋コンクリート構造物において,海水中の塩化物イオンがもとで生じる鉄筋腐食による早期劣化が発生している.塩化物イオンの浸透をどのように抑制するかは,構造物の長期耐久性を実現するための重要な課題である.各種の比較的短期間の実環境暴露試験や促進試験の結果から,スラグセメントを使用したコンクリートにおいては普通ポルトランドセメントを使用したコンクリートに比べて塩化物イオンの浸透が抑制されていることが明らかになっている.この抑制効果の長期的挙動を把握するために,3種の異なるシリーズの,スラグセメントを用いたコンクリートの長期暴露試験を港空研構内の海水循環水槽において実施した.これらのシリーズの暴露期間が各々30年,15年,10年に達したことから,供試体の評価試験を実施した.コンクリートの外観性状,圧縮強度,中性化深さ,含水率,コンクリートの電気抵抗,塩化物イオン含有量(全塩化物・可溶性塩化物),細孔構造,鉱物組成,埋設鉄筋の腐食状況,鉄筋-コンクリート界面の観察,を実施し,普通ポルトランドセメントコンクリートとの比較を行った.これらの一連の実験の結果を本文では取りまとめる.本文において述べられている結果は,海洋環境下におけるコンクリートの長期耐久性を考察する上で貴重な資料となるものである.
 長期間の暴露を経た供試体の試験結果では,スラグセメントを使用することによるマイナス面の効果は皆無であった.普通ポルトランドセメントを使用したコンクリートに比べて,スラグセメントコンクリートの方が長期的な強度の増進を示した.スラグセメントコンクリートの供試体の表層部は,長期間の暴露後に密実になる傾向を示し,それにより塩化物イオンが表層部で遮へいされていた.また,内部鉄筋の腐食もスラグセメントコンクリートの方が軽微であった.また,スラグセメントの方が緻密な細孔構造を示すと同時に,鉄筋-コンクリート界面構造も緻密であった.これより.スラグセメントコンクリートの方が長期耐久性に優れるものと判断された.
 また,上記の結果に加え,鉄筋-コンクリート界面に空隙が存在すると塩化物イオン濃度がかなり低くても鉄筋の腐食が開始されることから,海洋コンクリート構造物の長期耐久性を向上させるためには,鉄筋-コンクリート界面の構造を改善することが極めて重要であることが明らかとなった..
151. 濵田秀則,山路徹,Tarek U.M.,平崎敏史,小牟禮建一, コンクリート中鉄筋の電気化学的計測に影響を及ぼす要因に関する実験的考察, 港湾空港技術研究所 資料, 1040, 2003.03, [URL], コンクリート中鉄筋の腐食に関する性状を電気化学的に把握する際に用いられる計測が電気化学的計測である.実験の一環として実験室的に用いられる場合と,実構造物の調査の一環として現場で計測される場合とがある.電気化学的計測として,a)自然電極電位,b)分極抵抗,C)分極曲線,d)定電位ステップ試験,等の計測は多くの研究実績があり,概ね確立された計測方法であると言える.しかし,コンクリート中の鉄筋に対してこれらの計測を適用する場合,計測システム上の誤差の発生を避けることができない.計測データに誤差が生じる大きな要因として,1)コンクリートの内部に位置する鉄筋とコンクリート外部に位置する照合電極との間の液間電位差,2)コンクリートの内部に位置する鉄筋とコンクリートの外部に位置する対極(ステンレス鋼板)の間の電気抵抗,および,3)コンクリート中の含水状態,が挙げられる.上記の1)は主に自然電極電位の計測値に,2)は主に分極抵抗および分極曲線の計測値に,また3)は主に定電位ステップ試験の計測値に影響を及ぼす.
 本文においては,拡散セルのシステムを用いて実施した電気化学的計測の誤差評価に関する基礎実験について取りまとめる.すなわち,基本的なシステムを用いて実施した実験の結果を考察することにより,上記の要因が電気化学的計測の計測結果に及ぼす影響を定量的に把握するものである.
 得られた主要な結論は以下のとおりである.
1)自然電極電位は,照合電極と鉄筋間の液間電位差の影響を受ける.それに対して,鉄筋と照合電極間の抵抗の影響はむしろ小さい.
2)分極抵抗(直線分極抵抗)の計測値は,鉄筋と対極間の抵抗の影響を受ける.
3)分極曲線により判定される不動態のグレイドは,グレイドが小さい領域(鉄筋表面の不動態の状態があまりよくない状況)において,鉄筋と対極間の抵抗の影響を受ける場合がある.
4)定電位ステップ計測の計測結果は,コンクリートの含水率の影響を受ける.また,含浸されている溶液が海水か水道水かによりその影響は異なる..
152. 小牟禮建ー,濵田秀則,横田弘,山路徹, RC桟橋上部工の塩害による劣化進行モデルの開発 , 港湾空港技術研究所 報告 041-04-01, 41, 4, 3-38, 2002.12, [URL], 近年,鉄筋コンクリート構造物の塩害による早期劣化が重大な問題となっている.塩害による分化は,鉄筋コンクリートの耐荷性を担う鉄筋を腐食させ,構造物の著しい性能低下を引き起こす危険性がある.
 港湾構造物においてもそれは例外ではなく,特に直接海洋上に設置され,常時海水飛沫に曝された,非常に厳しい塩害環境にある桟橋上部工の被害は甚大であると考えられる.これらの桟橋を永く安全に使用するにあたっては,現在の劣化の実態を把握し,それに応じた適切な維持管理を行っていくことが重要である.
 本文は,平成9年度から平成13年度にかけて行った,全国から抽出した25の桟橋上部工の劣化実態調査の結果をまとめたものである.また,これらの調査結果を基に,桟橋上部工の維持管理を行う上で必要となる劣化進行モデルを作成したので,その内容について報告する..
153. 渡邉弘子,岩波光保,濵田秀則,横田弘, 海生生物付着による海洋構造物の耐久性向上に関する研究, 港湾空港技術研究所 報告 041-03-03, 41, 3, 49-105, 2002.09, [URL], 四方を海洋に囲まれた我が国では海洋環境下に位置する構造物が多いが,海洋構造物は塩分環境下に曝されており,特に,鉄筋コンクリート構造物としては非常に厳しい環境下にある.そのため,海洋コンクリート構造物の耐久性向上については,これまで種々の研究が行われてきた.一方,海洋環境にある干満帯及び海中部においては構造物表面に海生生物が付着し,このような箇所ではコンクリートの耐久性が相対的に向上することが経験的に知られてきた.しかし,海生生物は別名汚損生物と呼ばれ,海生生物の付着は一般的に忌避すべきこととして扱われてきた.それは,一部鋼構造物の腐食促進や海水利用放取水路の流量低下等,生物付着により構造物の機能低下が誘引されるためである.
 しかし,現在では地球規模での環境保全が重要かつ緊急課題であり,海洋環境下においても生物の棲息する豊かな自然環境の保護に努める必要が生じている.
 そこで本研究では,海洋コンクリート構造物の耐久性を向上させる表面被覆材料として海生生物に着目し,生物付着が耐久性向上に及ぽす効果を定量的に把握するとともに海生生物の有効利用について検討することを目的とした.本報告に述べる研究内容は以下のとおりである..
154. 青山敏幸,阿部正美,濵田秀則,福手勤,関博,井川一弘, 海洋環境下にあるプレテンション方式PC構造物への電気防食の適用に関する研究-暴露10年結果報告- , 港湾空港技術研究所資料, 1008, 2001.09, [URL], 本研究は,海洋環境下におけるPC構造物への電気防食適用性を検討するため,あらかじめコンクリートに塩化物イオンを9kg/m3混入し,海水散布環境下に10年間にわたり無防食状態,および「網状陽極」,「チタン線」,「亜鉛シート」,「導電性塗料」方式で電気防食を施したプレテンション方式PCはりについて,暴露終了後に実施した静的載荷試験,PC鋼材の腐食状況,PC鋼材引張試験,コンクリートの塩化物イオン含有量測定,陽極材の性能試験等の結果をとりまとめたものである.得られた主要な結論は以下の通りである.
1)暴露期間中の電気化学的測定により防食効果があると判断された「網状陽極」,「亜鉛シート」,「導電性塗料」方式は,腐食の程度が非常に軽微であり,電気防食による防食効果を確認した.
2)一方,電気化学的測定により防食効果なしと判定された「チタン線」方式,および無防食供試体は,PC鋼材の腐食が認められた.
3)電気防食による防食効果が得られた供試体は,PC鋼材の機械的性質も規格値以上を満足していた.
4)電気防食による防食効果が得られた供試体は,PCはりの力学的挙動も暴露前と同等の性能を有していた.一方,電気防食による防食効果を得ることができなかった「チタン線」方式,無防食供試体は,隅角部2本の鋼材の破断により,暴露前に実施した供試体に比べ終局荷重が約35%低下した..
155. Tarek Uddin MOHAMMED,濵田秀則,山路徹, Corrosion of RC Bars in RC Structures under Marine Environment Based on the Long-term Exposure Test, 港湾空港技術研究所 報告 040-03-03, 40, 3, 37-56, 2001.09, コンクリート中の鉄筋の腐食は海洋構造物の耐久性低下の最も大きな原因となっている.この問題に関しては,古くから多くの研究が実施されてきている.しかし,海洋環境下におけるRC構造物の長期耐久性を確保するためには,まだまだ多くの研究が必要である.このために,海洋環境下におけるコンクリート構造物の耐久性に関する重要な幾つかの点に関して長期の暴露試験を実施し,幾つかの結論を導いた.
 過去6年間にわたる一連の研究プログラムにおいて,コンクリート中鉄筋の電気化学的性質,物理的性質,例えば,鉄筋の配置方向が腐食に及ぽす影響,異型棒鋼と丸鋼の腐食状況の相違,コンクリートのひび割れが腐食に及ばす影響,普通セメント・高炉セメント・フライアッシュセメントといったセメントの種類が腐食に及ばす影響,などについて研究を実施してきた.本文においては,これらの研究より得られた結果を取りまとめ,以下に示す結論を得た.
1)鉄筋とコンクリートの間に空隙が存在する場合は,腐食発生時期を早めるとともに,一旦腐食が開始された鉄筋の腐食速度が大きくなる.
2)丸鋼に比べて異型棒鋼の方が腐食しやすい傾向にあった.
3)高炉スラグ置換率が比較的高い,高炉セメントC種が最も塩分浸透に対する抵抗性,内部鉄筋の腐食抵抗性が優れていた.
4)長期の暴露期間において,比較的幅の小さなひび割れは水和生成物により充填される傾向にあり,そのために内部鉄筋の腐食が抑制される傾向にあった..
156. 小菊史男,濵田秀則,山路徹,松永久宏, 鉄鋼スラグを用いた固化体の基礎的性状および港湾構造物への適用性に関する研究 , 港湾技研資料, 990, 2001.06, [URL], 近年,CO2による地球温暖化や天然原料の枯渇或いはその採取に伴う環境破壊が問題視され,循環型社会構築のためのいろいろな努力が始まっている.鉄鋼業において副生的に発生するスラグを用い,セメントを用いずに全量リサイクル資材を用いて,比重が大きく,アルカリ溶出が少ない固化体ができることを見出した.本研究は,スラグ固化体の基礎的性質と,海洋環境下での適用性評価を目的として,強度特性,波浪・漂砂などを想定した擦り減り特性,長期の安定性の目安とした高温海水養生による強度変化,沈設時に海域に及ぼす影響について検討したものである.
 スラグ固化体に関する本研究で得られた主な結論は,以下の通りである.
 1)コンクリート製造と同様な装置,同様な手順でスラグ固化体を製造することができる.
 2)ブリーディング量が小さく,しかもブリーディング水中への有害重金属の溶出が無い.
 3)固化相はカルシウムとシリカおよびアルミナの水和物である.
 4)スラグ固化体の比重は2.5程度で,普通コンクリートより1割近く大きくなる.
 5)スラグ固化体の標準養生における強度発現では,91日強度が28日強度の1.3倍になる.
 6)同じ圧縮強度の普通コンクリートと比較すると,曲げ強度,引張強度は同等だが,弾性係数が小さい傾向にある.
 7)擦り減り係数は,同じ圧縮強度の普通コンクリートと比べて小さい.即ち擦り減り抵抗性は大きい.
 8)60℃及び40℃の海水に6ヶ月浸せき後の圧縮強度は浸せき前の1.5倍になる.
 9)海水に暴露した場合,周囲の海水のpH上昇が普通コンクリートと比べて小さい.
 10)スラグ固化体は,無筋ブロック系の港湾構造物への適用は可能であると考えられる..
157. 濵田秀則,山路徹,坂本明,佐々木俊明,大坪貴明, 東京国際空港における窒素酸化物の排出に関する調査 , 港湾技研資料, 980, 2001.03, [URL], 本調査では,まず各種の資料を用いて空港内および空港周辺における窒素酸化物の排出源を推定し,その排出係数を調べた.また,窒素酸化物濃度が高いと想定される箇所について,窒素酸化物濃度の実態調査を行い,排出係数調査結果との関係について考察した.さらに,窒素酸化物濃度の高い箇所について,光触媒技術の適用による窒素酸化物濃度の低減の可能性について考察した.
 一連の調査より以下の結果を得た.
1)空港内および周辺における窒素酸化物の排出源の推定およびその排出係数の調査により,航空機から排出量が最も多いことが推定された.
2)2000年3月7日から3月10日にかけて実施した窒素酸化物濃度の実測の結果,空港内のリムジンバス発着所が最も窒素酸化物濃度が高く,空港外へのバス発着場周辺,およびエプロン(駐機場)においても窒素酸化物濃度が高くなっていることがわかった.
3)今回の調査結果から,バス乗り場周辺及び高速道路沿いにおいて光触媒技術を適用できる可能性があると考えられた.しかし,適用に際しては,日射量や相対湿度等の適用条件,ならびに触媒能力などについての詳細な検討を実施する必要がある..
158. 原田佳幸,阿部正美,福手勤,濵田秀則,是永正,江田和彦,岩倉肇,元木卓也,佐藤一昌, 重防食鋼矢板における被覆材の接着耐久性に関する研究, 港湾技研資料, 984, 2001.03, [URL], ポリエチレンまたはウレタンエラストマーで防食される重防食鋼矢板の防食効果や耐久性について評価した研究結果をまとめた.その主な項目としては,(1)実構造物調査,(2)屋外海水循環水槽における曝露試験,(3)室内での劣化促進試験,(4)維持管理方法の検討を行い,以下の結果を得た.
(1)1992~1996年度の実構造物の調査で特に異状は認められなかったが,1997年度の調査において一部の港湾で被覆端部に軽微な接着劣化が観測さた.
(2)屋外海水循環水槽における5年間の暴露試験で,被覆材の人工的な損傷部における各種部分補修方法の耐久性を確認し,いずれも錆の発生は見られず良好な供用性を確認した.
(3)室内劣化促進試験を行なった結果,被覆の接着劣化進展は腐食環境と相関し,その影響要因の一つとなっていることが判った.被覆の劣化進展速度をアレニウス法及び腐食速度と劣化進展速度の関係から予測した.
(4)塗覆装系に関する一般的な維持管理方法をベースに,重防食鋼矢板固有の維持管理方法として,点検・調査,健全度評価および補修方法を検討し,その一部を『港湾構造物の維持補修マニュアル』に反映させた..
159. 横田弘,山田昌郎,濵田秀則,横沢和夫,舟橋政司,原夏生,三輪俊彦,岡本享久,栩木隆,二羽淳一郎, 高性能軽量コンクリートの港湾構造物への適用に関する基礎的研究, 港湾技研資料, 967, 2000.09, [URL], 本資料は,高性能軽量コンクリートを用いて港湾構造物,特にケーソン式構造物を建造する可能性について検討したものである.つまり,軽い材料を用いて重さを必要とする構造物を作るという,逆転の発想を実現することを目的としている.軽量コンクリートは,人工軽量骨材を天然骨材に置換する方法によることが一般的である.従来の人工軽量骨材は,内部構造が連続空隙型であるために吸水量が大きく,その結果できあがるコンクリートは力学性能や耐久性に問題があり,厳しい海洋環境下では十分に適用されなかった.しかし,これらの欠点を改善した独立空隙型の人工軽量骨材が最近開発されつつあり,高強度や高耐久性が実現できるほか,さらなる軽量化も図れるようになった.このような骨材を用いてケーソン式構造物を建造するには,基礎的な力学性能や耐久性能を明確にする必要がある.ここでは,特に力学性能を中心として検討した結果を述べた.また,軽量化による施工上の制約の払拭により,建設費が低減できる可能性があることを試設計により示した..
160. 早川健司,山路徹,濵田秀則, 海洋環境下における再生コンクリートの耐久性に関する研究, 港湾技術研究所 報告, 39, 2, 153-177, 2000.06, [URL], コンクリート解体材から製造される再生骨材をコンクリート用骨材として利用するための技術開発は,我が国において重要な課題になっている.本研究は,再生コンクリートを海洋環境下のコンクリート構造物へ適用するための基礎資料を得ることを目的としている.すなわち本研究の目的は耐海水性に優れる高炉セメントB種を用いた再生コンクリートの諸特性,特に耐海水性や鉄筋防食性能を,普通ポルトランドセメントおよび高炉セメントB種を用いた普通コンクリートと比較して定量的に把握することである.このため,骨材品質を変化させた再生コンクリート供試体を作製して乾燥収縮,耐凍害性,中性化などを検討するとともに,促進劣化試験および長期暴露試験を実施して耐海水性や鉄筋の防食性能に関する試験を実施した.その結果,高炉セメントB種を用いた再生コンクリートの強度発現特性は,普通コンクリートの場合と同様に長期的には普通ポルトランドセメントを用いた場合と同等となこと,高炉セメントB種を用いることにより,再生コンクリートの耐海水性を向上させることができること,再生コンクリートの塩化物イオンの拡散性状は,高炉セメントB種の使用により普通ポルトランドセメントを使用した普通コンクリートと同等以上にすることができることなどが示された..
161. 阿部正美,濵田秀則,真壁知大,西澤信二, 海洋鋼構造物の被覆防食工法に関する長期試験, 港湾技研資料, 952, 2000.03, [URL], 鋼材は,海洋・港湾構造物を建設するための重要な建設材料であるが,その利用にあたっては信頼性の高い防食法を適用することが不可欠である.各種防食法の防食効果や耐久性を評価するには,実際の海洋環境下で長期間追跡調査することが,現在では最も信頼性の高い方法と考えられている.
 著者等は桟橋構造物の鋼管杭に各種被覆防食を適用し,それらの防食効果の経年変化を調べ,技術改良を行っている.10年間にわたる追跡調査の結果,各防食法とも概ね満足すべき結果を示したが,保護カバ-を用いる工法ではカバ-等は波力に耐える強度が必要であること,塗装にはジンクリッチの下塗りが必要であること,電気化学的モニタ-法には改良の余地があることなどが明らかとなった..
162. 横田弘,秋山哲治,濵田秀則,三上晃,福手勤, 海洋環境(酒田港20年)に暴露したコンクリート梁の材料劣化が梁の力学性能に及ぼす影響, 港湾技術研究所報告, 38, 2, 169-222, 1999.06, [URL], 構造物の適切な維持管理をするためには,劣化・損傷程度に応じた補修,補強あるいは更新が要求される.そのため,劣化の生じた構造物における現時点での耐力評価,耐用年数に達するまでの残存機能等を定量的に把握することは極めて重要である.そこで,実際の海洋環境に20年以上暴露したコンクリート梁について,静的載荷試験を行いその耐荷性状を調べた.また,圧縮強度試験等の物理試験,内部鉄筋の腐食状況や塩化物含有量等の化学分析を行い,コンクリートの材料劣化について考察し,梁の耐荷性状に及ぼす影響を検討した.その結果,コンクリートの材料強度に概ね低下はなかったが,塩化物含有量の増加,骨材反応等が確認された.また,梁の耐荷性能は内部鉄筋の腐食が確認されたものの優れた性能を有していた..
163. 濵田秀則, RC港湾構造物の塩害に係わる環境要因の定量的評価に関する研究, 港湾技術研究所報告, 38, 2, 299-394, 1999.06, [URL], 我が国において,鉄筋コンクリート港湾構造物,特に桟橋上部工の塩害による劣化が顕在化している.このため,塩害を受けている既存構造物の補修設計法,および塩害を受けることが想定される環境に今後建設される新設構造物の耐久設計法の確立が望まれている.これらの設計法を確立するためには,構造物が置かれている環境条件を定量的に評価することが必要不可欠であるものの,このテーマに関する研究はこれまでにあまりなされていない.このような状況に鑑み,本研究においては,RC港湾構造物の塩害に係わる環境要因を定量的に評価することを目的としている.本研究は,鉄筋を埋設した比較的小型のモルタル供試体の全国規模の暴露試験およびその解析に基づく環境要因の定量的評価,ならびにその結果の耐久設計への応用法について検討したものである..
164. 大即信明、山本邦夫、濵田秀則, CFRPロッドを緊張材としたアンボンドPC梁の曲げ性状, 港湾技術研究所報告, 27, 2, 241-283, 1998.06, [URL].
165. 田中順,福手勤,濵田秀則,堂園昭人, 再生骨材を使用したコンクリートの材料特性に関する研究, 港湾技術研究所報告, 36, 3, 37-60, 1997.09, [URL], 本研究においては,はじめに製造方法の違いが再生骨材の品質におよぼす影響を,各種骨材試験によって調査した.こうしてその物性が明らかになった再生骨材を比較検討し,再生骨材を使用したコンクリートの製造を行った.特に再生骨材を使用したコンクリートの物性に影響を及ぼす主要因が粗骨材界面の旧モルタル部分,あるいは再生骨材製造過程で多量に発生し,再生細骨材中に含まれる微粒分量の割合であると考え,普通骨材と再生骨材の混合比率および水セメント比を変化させたコンクリートを製造し,力学的特性,耐久性等の観点から,その材料特性を検討した.また,コンクリート製造時に顔料を添加し,新モルタル部分を着色した供試体を用いて破壊時の断面の目視観察を行った.その他,約1年間,海洋環境をシミュレートした海水循環水槽や高温海水水槽での暴露実験も実施した.
 得られた主要な結論は以下の通りである.
(1)再生粗骨材は,旧コンクリートのモルタル付着,混入等により普通骨材と比較してその性能は劣るが,表面のモルタルを除去することにより,その品質は普通粗骨材に近くなった.
(2)再生骨材コンクリートは,再生細骨材中の微粒分等の影響で,またコンクリートに使用されていた粗骨材が良質であったため良好な流動性を示した.
(3)再生骨材コンクリートの強度特性は普通骨材のみを使用したコンクリートに比べ強度は低いが,水セメント比を下げることにより強度を増加させることはできる..
166. 濵田秀則,福手勤,阿部正美,堂園昭人, 劣化した港湾コンクリート構造物の非破壊検査法としてのAE計測の適用性に関する基礎的研究, 港湾技研資料, 872, 1997.06, [URL], これまでに大量に建設されてきた港湾コンクリート構造物において徐々に劣化,老朽化が進んでいる.今後,これらの構造物の信頼性を維持し,将来にわたり長期的に供用していくためには合理的なメンテナンスを施していくことが不可欠である.コンクリート構造物のメンテナンスの一環として,構造物をさほど傷つけない非破壊検査は極めて重要な位置を占める.
 一方,コンクリート構造物の非破壊検査法の一手法としてAE(アコースティック・エミッション)計測がある.ここ10数年来,コンクリート工学の分野においてもAE計測に関する基礎的研究が行われ,現在では実用化への端緒が開かれつつある.本研究においては,AE計測を劣化の進行した港湾コンクリート構造物の非破壊検査の一手法として適用していくことを目的とした実験的検討を行った.本実験の結果より,以下に示すような結論が得られた.
1)コンクリートの圧縮載荷時において得られたAE計測結果に対するレートプロセス解析値は,コンクリートの細孔構造と関係がある.これより,海水の作用により生じるコンクリートの細孔構造の変化をレートプロセス解析により把握することが可能である.
2)内部鉄筋が腐食したRC(鉄筋コンクリート)はりの曲げ載荷時において発生するAEには以下のような特徴がある.すなわち,載荷の低荷重レベルのひびわれ発生の状況と関係がある.この現象を利用することにより,内部鉄筋が腐食したRCはりの劣化度判定法としてAE計測を適用できる可能性がある..
167. 濵田秀則,福手勤,石井光裕, 混和材として分級フライアッシュを用いたコンクリートの港湾・海洋構造物への適用性に関する研究 , 港湾技術研究所報告, 35, 4, 75-100, 1996.12, [URL], フライアッシュあるいは高炉スラグ微粉末といった鉱物質混和材をコンクリートに使用していくことは様々な国において実施されている.一方,我が国においても今後石炭火力発電においてフライアッシュが大量に発生することが予想されている.フライアッシュから微粒分のみを抽出し全体としての品質の安定性の向上を目指した試みの一つが分級であり,分級により得られたフライアッシュが分級フライアッシュである.
 本研究は,この分級フライアッシュを港湾構造物をはじめ海洋環境下において建設される構造物へ適用していくための基礎データを得ることを目的としている.すなわち,分級フライアッシュを用いたコンクリートの耐海水性ならびに内部鉄筋の防食性を,他のコンクリートと比較して定量的に把握することを目的としている.
 本研究より得られた主要な結論を以下に要約する.
1)分級フライアッシュを混入することにより,コンクリートの表層部分の乾湿繰返しおよび温度変化の繰返しに対する抵抗性が向上する.
2)分級フライアッシュを混入することにより,圧縮強度の低下率を抑制することができる.
3)分級フライアッシュを混入することにより,引張強度の低下率を抑制することができる.
4)分級フライアッシュを混入することにより,コンクリート中の塩化物イオンの拡散を抑制できる.
5)分級フライアッシュを混入することにより,コンクリートの電気抵抗を小さくすることができる.
6)分級不アイアッシュを混入したコンクリートの場合でも,水結合材比を小さくする60方が内部鉄筋の防食上有利である.
7)今後海洋環境下において建設,供用される港湾・海洋構造物へ,分級フライアッシュを適用していくことは十分可能である..
168. @福手勤,濵田秀則,田中順,真下昌章, 海洋環境下における植栽を目的としたポーラスコンクリートの材料特性 , 港湾技研資料, 819, 1995.12, [URL], わが国各地の港湾整備において,構造物本来の機能を満足しつつ,景観や親水性に配慮した施設の整備が進んでいる.この流れの中にコンクリート構造物に対する緑化の要請がある.このような背景から,本稿では,草本類,木本類が根を張ることを可能とし,植物の生育が可能となるポーラスコンクリートを開発することを目的とした材料実験の結果を示している.
 実験は29種類の配合のポーラスコンクリートに対して各種の試験を行った.実験パラメータは(1)骨材の粒径分布,(2)混和材の有無(なし,シリカフューム,高炉スラグ微粉末),(3)混和材置換率,(4)水結合材比,(5)結合材骨材比などである.また評価項目は,(1)強度,(2)空隙率,(3)透水性,(4)アルカリ溶出量,(5)耐海水性などである.
 一連の実験の結果,以下のような結論を得た.
(1)混和材として高炉スラグ微粉末を用いることにより25%程度の空隙率で200kgf/平方センチメートル程度の圧縮強度のポーラスコンクリートを得た.
(2)ポーラスコンクリートの強度特性は,主に空隙率,ペースト量により左右される.
(3)多孔質であることによる引張強度の低下は圧縮強度の低下よりも大きいため,引張強度と圧縮強度の比は一般のコンクリートよりも小さい.
(4)ポーラスコンクリートから溶出するアルカリイオン量はセメント量,混和材の影響を受けるが,いずれも水への浸漬時間の経過とともに減少する.
(5)強制的な乾湿繰り返しは,ポーラスコンクリートのペースト膜に細かいひび割れを発生させ,強度,動弾性係数などに影響を及ぼす..
169. 濵田秀則,R. Narayan Swamy, 種々の海洋環境下におけるコンクリート中への塩化物イオンの浸透に関する一考察, 港湾技研資料, 810, 1995.09, [URL], 本研究の目的は,海洋環境の様々な部分に暴露されたコンクリート中への塩化物イオンの浸透過程および浸透量について考察することである.
 コンクリート中の塩分含有量は,コンクリート内部の鉄筋の腐食の開始,腐食の規模および速度を支配する主要な要因の一つである.様々な海洋環境下におけるコンクリート中の塩分含有量に関しては,これまでに多くの研究データが得られている.しかし,それらを記述している文献は広範囲にばらついており,またそれらの文献が取り扱っている変数も多数であるのが実情である.このような広範囲の情報を関連づけ,海洋環境下におけるコンクリート中への塩化物イオンの浸透過程および浸透量に関して総合的に考察しようとする試みはこれまでには報告されていない.
 本研究は,これまでに多くの研究論文中において示されてきた海洋観光下におけるコンクリート中の塩分含有量のデータを総合的に取りまとめ,それを基に海洋環境下におけるコンクリート中への塩化物イオンの浸透過程および浸透量について考察するものである..
170. 阿部正美、福手勤、濵田秀則、三浦幸治, コンクリート中鉄筋のマクロ腐食と電気防食によるアノード、カソードへ流入する電流量および分極量, 港湾技術研究所報告, 32, 2, 181-205, 1994.06, [URL].
171. 福手勤、三浦幸治、濵田秀則、寺野宜成, 転圧コンクリートによる薄層オーバーレイ工法の開発, 港湾技術研究所報告, 33, 2, 207-229, 1994.06, [URL].
172. 福手勤、濵田秀則、三浦幸治、中島由貴、佐野清史、守分敦郎、濱崎勝利, 増粘剤を用いた高流動コンクリートの過密配筋部材への適用性, 港湾技術研究所報告, 33, 2, 231-257, 1994.06, [URL].
173. Tsutomu FUKUTE, Hidenori HAMADA, A Study on the Durability of the Concrete Exposed in Marine Environments for 20 Years, Report of the Port and Harbour Research Institute, 31, 5, 251-272, 1993.03.
174. 阿部正美、福手勤、濵田秀則、三浦幸治, 港湾における鉄筋コンクリート構造物への流電陽極方式による電気防食の適用に関する基礎的試験, 港湾技研資料, 740, 1992.09, [URL].
175. 濵田秀則、福手勤、阿部正美, 塩害を受けた鉄筋コンクリート部材の補修効果に関する実験, 港湾技研資料, 725, 1992.03, [URL].
176. 濵田秀則、福手勤、阿部正美、山本邦夫, コンクリート表面被覆の塩害防止効果ならびにその評価法について, 港湾技研資料, 706, 1991.06, [URL].
177. 福手勤、濵田秀則、山本邦夫, 港湾コンクリート構造物に発生した亀甲状のひび割れの原因調査および対策に関する考察, 港湾技研資料, 694, 1991.03, [URL].
178. 阿部正美、福手勤、濵田秀則、山本邦夫, 海水飛沫を受ける鉄筋コンクリート構造物への電気防食工法の適用に関する基礎的研究, 港湾技研資料, 695, 1991.03, [URL].
179. 福手勤、山本邦夫、濵田秀則, カラーコンクリートの材料特性に関する研究 ー強度特性、色彩特性および耐久性ー, 港湾技術研究所報告, 30, 1, 313-345, 1991.03, [URL].
180. 濵田秀則、福手勤、阿部正美, 鋼ーコンクリートハイブリッド部材の海洋環境下における耐久性, 港湾空港技術研究所報告, 29, 4, 119-168, 1990.12, [URL].
181. 福手勤、山本邦夫、濵田秀則, 海水を練り混ぜ水とした海洋コンクリートの耐久性に関する研究, 港湾空港技術研究所報告, 29, 3, 57-93, 1990.09, [URL].
182. 山本邦夫、大即信明、濵田秀則, ループ状のアラミド繊維ロープを緊張材としたPC梁の曲げ試験, 港湾技研資料, 695, 1989.03, [URL].
183. 大即信明、濵田秀則、原茂雅光, 各種補修を施したコンクリート梁の促進海水養生試験, 港湾技研資料, 631, 1988.12, [URL].
184. 大即信明、原茂雅光、濵田秀則, 桟橋コンクリート上部工劣化実態詳細調査報告, 港湾技研資料, 627, 1988.09, [URL].
185. 濵田秀則、大即信明、原茂雅光, 酒田港および鹿児島港に暴露したコンクリート梁の耐海水性(材齢10年結果報告), 港湾技研資料(運輸省港湾技術研究所), 614, 1988.06, [URL].
186. 大即信明、原茂雅光、濵田秀則, 桟橋コンクリート上部工劣化実態概略調査報告, 港湾技研資料(運輸省港湾技術研究所), 617, 1988.06, [URL].
187. 大即信明、濵田秀則、原茂雅光, 鉄筋およびプレストレストコンクリートパイルの耐海水性(材齢10年結果報告), 港湾技研資料(運輸省港湾技術研究所), 605, 1988.03, [URL].
188. 大即信明、原茂雅光、濵田秀則, コンクリートの各種打継目の耐海水性(材齢10年結果報告), 港湾技研資料(運輸省港湾技術研究所), 606, 1988.03, [URL].
189. 大即信明、原茂雅光、濵田秀則, 沖縄産骨材を用いたコンクリートの耐海水性(材齢10年結果報告), 港湾技研資料(運輸省港湾技術研究所発行), 597, 1987.09, [URL].
190. 池田隆徳・川端雄一郎・松下博通・濵田秀則, モルタルのDEF膨張に及ぼすセメント及び骨材種類の影響, コンクリート工学年次論文集, Vol.29, No.1, pp.987-992.

九大関連コンテンツ

pure2017年10月2日から、「九州大学研究者情報」を補完するデータベースとして、Elsevier社の「Pure」による研究業績の公開を開始しました。